Evidence map›Paper›PMID 42305895›Full record

ArticleJournal of experimental orthopaedics2026

Anatomical 3D-printed metaphyseal cone in revision total knee arthroplasty: A short-term clinical and radiological follow-up evaluation.

Federica Rosso, Vincenzo Mattiacci, Matteo Bruzzone, Federico Dettoni, Umberto Cottino, Roberto Rossi

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Federica RossoDepartment of Orthopaedics and Traumatology, AO Ordine Mauriziano University of Torino Torino Italy.ORCID https://orcid.org/0000-0002-6085-3676
Vincenzo MattiacciDepartment of Orthopaedics and Traumatology Università degli Studi di Torino Torino Italy.ORCID https://orcid.org/0009-0007-8303-735X
Matteo BruzzoneDepartment of Orthopaedics and Traumatology, AO Ordine Mauriziano University of Torino Torino Italy.ORCID https://orcid.org/0009-0002-9266-6741
Federico DettoniDepartment of Orthopaedics and Traumatology Ospedale Cardinal Massaia Asti Italy.ORCID https://orcid.org/0000-0003-3216-0474
Umberto CottinoDepartment of Orthopaedics and Traumatology, AO Ordine Mauriziano University of Torino Torino Italy.ORCID https://orcid.org/0000-0002-2538-4923
Roberto RossiDepartment of Orthopaedics and Traumatology, AO Ordine Mauriziano University of Torino Torino Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Bone loss is commonly encountered during revision total knee arthroplasty (R-TKA), and metaphyseal cones are often used to address these defects. In addition, they can enhance Zone 2 fixation in R-TKA in the presence of poor bone quality. The aim of this study was to evaluate the short-term clinical and radiological outcomes of a novel three-dimensional (3D)-printed metaphyseal cone in R-TKA. Methods: This single-centre, single-surgeon prospective study included all patients who underwent R-TKA using a novel 3D-printed anatomical metaphyseal cone (AMF, ENOVIS®) with a minimum follow-up of 24 months. Patient demographics and operative details were recorded. Postoperative assessments included the Knee Society Score (KSS), Oxford Knee Score (OKS) and Short Form-12 (SF-12). Radiographic evaluation focused on radiolucent lines, implant or cone loosening and the cone's ability to replicate proximal tibial anatomy. Complications, reoperations and revisions for any reason were documented. Results: Thirty patients (31 knees) underwent R-TKA with a total of 48 cones (24 tibial and 24 femoral), with a mean follow-up of 37.3 months (standard deviation [SD] 8.8). In 48.4% of cases, cones were used on both the tibial and femoral sides. No intraoperative fractures occurred during cone preparation. All patients demonstrated significant improvement in clinical outcomes. Radiographic evaluation showed no evidence of cone loosening and accurate reproduction of proximal tibial anatomy. Survivorship free from cone revision, including for aseptic loosening, was 100%. Survivorship free from any revision or reoperation was also 100%. Conclusion: This novel 3D-printed anatomical metaphyseal cone demonstrated excellent short-term outcomes, with no early loosening and accurate replication of proximal tibial morphology. However, longer-term follow-up and a larger cohort are required to confirm these preliminary findings. Level of Evidence: Level IV.

Indexed as

arthroplastyconeskneemetaphysealrevision

Identifiers

PMID42305895
PMCPMC13266273

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.