Evidence map›Paper›PMID 42305725›Full record

ArticleArchives of academic emergency medicine2026

Comparing the Accuracy of Patient-Perceived Fever, Manual Fever Checking, and Non-Contact Frontal Infrared Thermometer; A Cross-sectional Study.

Moojan Shabani-Kakroudi, Mohammad Jalili, Ali Pasha Meysamie, Atousa Akhgar, Hamideh Akbari, Mahdi Zangi, Mehrnoosh Aligholi Zahraie, Saeed Aqavil-Jahromi, Mohammad Eftekhari

Abstract read
In one paragraph

Article in Archives of academic emergency medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Moojan Shabani-KakroudiEmergency Medicine Department, Imam Khomeini Hospital Complex (IKHC), Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
Mohammad JaliliEmergency Medicine Department, Imam Khomeini Hospital Complex (IKHC), Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
Ali Pasha MeysamieEmergency Medicine Department, Shariati hospital, Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
Atousa AkhgarEmergency Medicine Department, Imam Khomeini Hospital Complex (IKHC), Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
Hamideh AkbariEmergency Medicine Department, Imam Khomeini Hospital Complex (IKHC), Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
Mahdi ZangiEmergency Medicine Department, Shariati hospital, Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
Mehrnoosh Aligholi ZahraieEmergency Medicine Department, Imam Khomeini Hospital Complex (IKHC), Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
Saeed Aqavil-JahromiEmergency Medicine Department, Imam Khomeini Hospital Complex (IKHC), Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
Mohammad EftekhariEmergency Medicine Department, Imam Khomeini Hospital Complex (IKHC), Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Non-contact frontal infrared thermometers (NCFITs) have gained popularity following the COVID-19 pandemic, but their accuracy remains debated. This study compared the accuracy of three index tests of patient-perceived fever (PPF), manual fever checking (MFC) by emergency nurses, and NCFIT against tympanic thermometer (TT). Methods: This single center, diagnostic accuracy study evaluated adult patients in the triage area of the emergency department (ED) between May and September 2023. Five emergency nurses (ENs) examined patients using convenience sampling with index tests, followed by TT measurement for fever detection as standard test (T≥38°C). The sensitivity, specificity, positive and negative likelihood ratios (PLR and NLR) and accuracy, of PPF, MFC, and NCFIT in detecting the fever were measured and reported with 95% confidence interval (CI). The inter-rater reliability of ENs for MFC among 10 patients (outside the study) was 100%. Results: We included 279 patients with the mean age of 52.2 ± 16.98 years (51.97% male). TT identified 147 as febrile and 132 as non-febrile. The most sensitive index test was MFC, achieving 100% (95%CI: 97.5-100.0) sensitivity, 0 NLR, and 8.25 (95%CI: 5.7-12.1) PLR, with moderate accuracy (93.9% (95%CI: 89.9-96.0)). NCFIT demonstrated the lowest sensitivity (85.71% (95%CI: 78.9-90.9)) but the highest specificity (98.48% (95%CI: 93.6-99.5)) and accuracy (97.5% (95%CI: 93.1-99.8)). When the fever threshold for NCFIT was lowered to 37.5°C, sensitivity increased to 99% (95%CI: 97.4-99.9), NLR decreased to 0.01 (95%CI: 0-0.6), and PLR rose to 49.5 (95%CI: 20.8-90.2), while specificity remained at 98% (95%CI: 94-99.6). Conclusion: MFC/PPF could rule out fever but required NCFIT/TT to rule it in. However, NCFIT achieved the highest NLR and PLR when its fever threshold was set at 37.5 °C.

Indexed as

Emergency nursing;FeverSkin temperatureThermometersTouch

Identifiers

PMID42305725
PMCPMC13265967

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.