Evidence map›Paper›PMID 42302651›Full record

ArticleJACC. Advances2026

Artificial Intelligence for the Detection of Hypertrophic Cardiomyopathy From Standard Electrocardiogram.

Jakob Park, Jonathan Kermanshahchi, Christopher J Love, Klevin Roger Reyes, Alexander Kukuev, Sarit Meshesha, Katia Kon, Florian Rader

Abstract read
In one paragraph

Article in JACC. Advances, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jakob ParkSmidt Heart Institute, Department of Cardiology, Cedars-Sinai Medical Center, Los Angeles, California, USA. Electronic address: jakobpark0@gmail.com.
Jonathan KermanshahchiCalifornia University of Science and Medicine, Colton, California, USA.
Christopher J LoveViz.ai Inc, San Francisco, California, USA.
Klevin Roger ReyesSmidt Heart Institute, Department of Cardiology, Cedars-Sinai Medical Center, Los Angeles, California, USA.
Alexander KukuevSmidt Heart Institute, Department of Cardiology, Cedars-Sinai Medical Center, Los Angeles, California, USA.
Sarit MesheshaViz.ai Inc, San Francisco, California, USA.
Katia KonViz.ai Inc, San Francisco, California, USA.
Florian RaderSmidt Heart Institute, Department of Cardiology, Cedars-Sinai Medical Center, Los Angeles, California, USA. Electronic address: https://twitter.com/RaderFlorian.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHypertrophic cardiomyopathy (HCM) is often diagnosed late, increasing avoidable risk and delaying treatment. Artificial intelligence (AI) for 12-lead electrocardiograms (ECGs) may identify undetected HCM earlier.

objectivesThis study aimed to evaluate the performance of an AI algorithm for HCM detection and identify predictors of correct classification.

methodsOf 314 patients with cardiac magnetic resonance imaging (cMRI) for suspected HCM, 150 had analyzable ECGs and confirmed HCM by physician review of medical records and cMRI (ground truth). Eighty-three control patients without cardiomyopathy were included. A proprietary algorithm, Viz HCM (Viz.ai, Inc), labeled ECGs as HCM-positive or HCM-negative; the ECG closest to each patient's cMRI date was compared to ground truth. Diagnostic performance was evaluated by the area under the curve of the receiver-operating characteristic curve and at the prespecified threshold. Predictors of correct detection were determined by multivariable logistic regression for age, sex, race, maximal wall thickness, and hypertrophy subtype.

resultsThe mean age of all 233 patients was 56 years, and 62% were male. The algorithm identified HCM with an area under the curve of 0.946 (95% CI: 0.916-0.970), sensitivity of 58% (95% CI: 50.0%-65.6%), and specificity of 100% (95% CI: 95.6%-100%). Apical subtype was a significant predictor of correct detection (adjusted OR: 4.71; 95% CI: 1.71-15.48; P = 0.005). In 9 of 28 patients with ECGs available at least 1 year prior to cMRI, the algorithm detected HCM 2.6 years (median) before clinical diagnosis.

conclusionsThe AI ECG algorithm demonstrated highly specific HCM detection confirmed by cMRI and may improve early identification of unrecognized HCM.

Indexed as

artificial intelligenceelectrocardiogramhypertrophic cardiomyopathyscreening

Identifiers

PMID42302651
PMCPMC13292683

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.