Evidence map›Paper›PMID 42301300›Full record

ArticleRadiation and environmental biophysics2026

Quantifying measurement uncertainties in diode-based in-vivo dosimetry for Cobalt-60 high dose rate brachytherapy.

Dilson Lobo, Johan Sunny, M S Pooja, Challapalli Srinivas, M S Athiyamaan, Sourjya Banerjee, Abhishek Krishna, Paul Simon

Abstract read
In one paragraph

Article in Radiation and environmental biophysics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Dilson LoboDepartment of Radiation Oncology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India.
Johan SunnyDepartment of Radiation Oncology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India. johan.sunny@manipal.edu.
M S PoojaDepartment of Radiation Oncology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India.
Challapalli SrinivasDepartment of Radiation Oncology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India.
M S AthiyamaanDepartment of Radiation Oncology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India.
Sourjya BanerjeeDepartment of Radiation Oncology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India.
Abhishek KrishnaDepartment of Radiation Oncology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India.
Paul SimonDepartment of Radiation Oncology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High-dose-rate (HDR) brachytherapy provides a highly conformal cancer treatment modality by exploiting steep dose gradients, and achieving excellent tumour control while minimising radiation exposure to healthy tissues. In-vivo dosimetry (IVD) serves as an essential quality assurance tool, offering independent verification of delivered dose. However, its accuracy can be affected by several measurement-related uncertainties. This study aimed to characterise diode-based IVD for Co-60 HDR brachytherapy and quantify the uncertainties influencing detector performance. A Co-60 HDR afterloading system (SagiNova

Indexed as

BrachytherapyCobalt RadioisotopesIn Vivo DosimetryRadiometryCalibrationHumansPhantoms, ImagingRadiotherapy DosageUncertaintyCobalt-60Cobalt RadioisotopesCobalt-60Diode detectorDose accuracyHDR brachytherapyIn-vivo dosimetryMeasurement uncertaintyQuality assuranceRadiation dosimetrySDG 3: Good Health and Well-beingSDG 9: Industry, Innovation, and Infrastructure

Identifiers

PMID42301300
PMCPMC13486103

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.