Evidence map›Paper›PMID 42298257›Full record

ArticleEmergency radiology2026

Impact of virtual monoenergetic images on the assessability of lower extremity arteries in (Poly-) trauma photon-counting detector CT.

Daniel Dillinger, Christian Bauer, Hanns L Kaatsch, Achim Neufang, Achim Hagen, Stephan Waldeck, Daniel Overhoff

Abstract read
In one paragraph

Article in Emergency radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Daniel Dillinger *Department of Vascular and Endovascular Surgery, Federal Armed Services Hospital Koblenz, Ruebenacher Str. 170, Koblenz, 56072, Germany. danieldillinger@bundeswehr.org.ORCID http://orcid.org/0000-0003-2088-0167
Christian Bauer *Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, Koblenz, Germany.
Hanns L KaatschDepartment of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, Koblenz, Germany.
Achim NeufangDepartment of Heart and Vascular Surgery, University Medical Center Johannes Gutenberg University Mainz, Mainz, Germany.
Achim HagenDepartment of Vascular and Endovascular Surgery, Federal Armed Services Hospital Koblenz, Ruebenacher Str. 170, Koblenz, 56072, Germany.
Stephan WaldeckDepartment of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, Koblenz, Germany.
Daniel OverhoffDepartment of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, Koblenz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundComputed tomography (CT) is state of the art imaging modality in patients after severe trauma. A double-bolus contrast media protocol can be used to combine both arterial and parenchymal contrast in one scan. In case of lower extremity trauma, the CT scans can be extended to include the legs in order to rule out vascular pathologies. Virtual monoenergetic (VME) images derived from a Photon-Counting detector CT (PCDCT) proved to be helpful in vascular diagnostics and could therefore also add information in these extended trauma scans. Aim of this study was to determine the VME reconstructions with sufficient vascular contrast (> 200 Hounsfield Units) and to examine, which VME level has best specificity and sensitivity as well as best subjective vascular visibility.

methodsIn a retrospective analysis, we identified 34 patients undergoing extended whole-body trauma scans including lower extremities on a PCDCT with pathologies of the lower extremity arteries (extravasation, dissection etc.) and paired them with 34 patients without vascular pathologies. We measured CT values and noise of six vascular segments on energy levels 40 to 190 keV and calculated signal to noise (SNR) and contrast to noise (CNR) ratio. Subjective ratings for vascular visibility were performed on a five point Likert scale and two readers analyzed the images for vascular lesions across four energy levels (40, 70, 90 and 110 keV).

resultsCT attenuation was measured above 200 HU below 88 keV in the common femoral artery, below 86 keV in the superficial femoral artery and below 85 keV in the popliteal artery. For the tibial arteries, we found higher CT values above 200 HU at the energy levels below 87 keV. Noise was highest at 40 keV for all energy levels, SNR and CNR for common femoral artery was highest at 40 keV. Sensitivity peaked at 40 keV (78.4%) and showed decreasing values for higher energy levels. Specificity increased with higher keV levels up to 91.7%. 40 keV showed the highest sum of Likert ratings regarding vascular visibility.

conclusionPCDCT derived VME reconstructions below 86 keV showed sufficient vascular contrast in extended whole-body trauma scans after double-bolus contrast media administration. Smaller vessel depiction can be hampered by increased noise on lower energy levels resulting in decreased image parameters. Lower energy levels have the potential to improve the detection of vascular pathologies, such as bleeding and vascular occlusions.

Indexed as

Leg InjuriesLower ExtremityMultiple TraumaTomography, X-Ray ComputedVascular System InjuriesAdultAgedContrast MediaFemaleHumansMaleMiddle AgedRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesSensitivity and SpecificityContrast MediaCT angiographyPhoton counting detector CTTrauma

Identifiers

PMID42298257
PMCPMC13633378

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.