ArticleEJNMMI physics2026
Limitations in diagnostics and quantification of small lesions with low uptake in the clinical context of prostate
Article in EJNMMI physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe aim of this study was to investigate the limits of diagnostics and therapy planning for patients with prostate cancer using non-time-of-flight
methodsPET/MRI measurements were performed using a small lesion NEMA phantom. PET data were acquired for nine different activity concentrations (AC). Data of a longer single-bed protocol in the pelvis or a shorter whole-body protocol were reconstructed using relative or absolute scatter correction (SC). PET images were analysed considering a ± 25% deviation range between imaged and true AC as acceptable. Thirteen PSMA-PET/MRI patients with primary lesions or lymph node metastasis < 12 mm in the pelvis were included in this study. The presence of the halo artefact was evaluated in six
resultsFor both radiotracers, the 9.7 mm sphere was still visible at 0.16 kBq/mL with emission times > 40 min. The 3.7 mm sphere was only detectable at 22 kBq/mL with emission times > 4 min. All spheres ≥ 6.5 mm provide acceptable quantification at an AC of 1.32 kBq/mL for
conclusionsThe results demonstrated that the detection of lesions in the sub-centimetre range and a reliable quantification of