Evidence map›Paper›PMID 42296098›Full record

ArticlePloS one2026

Development and validation of the TexCoMP model: A nonlinear framework for optimising slip-resistant walkway coatings in diverse environments.

In-Ju Kim

Abstract readValidation Study
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

In-Ju KimDepartment of Industrial Engineering and Engineering Management, College of Engineering, University of Sharjah, Sharjah, United Arab Emirates.ORCID https://orcid.org/0000-0001-5781-4636

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSlip-related accidents remain a significant safety concern in public walkways, healthcare facilities, and industrial environments, particularly under contaminated surface conditions. Although numerous studies have investigated slip resistance using friction measurements and statistical classification approaches, existing predictive models often rely on simplified linear relationships or data-driven algorithms that provide limited physical interpretability of tribological interactions.

objectivesThis study aims to experimentally evaluate the slip-resistance performance of coated ceramic walkway surfaces under varying environmental conditions and to develop an interpretable, nonlinear, predictive framework, termed TexCoMP (Texture-Coating-Material-Performance), that integrates coating properties, surface texture characteristics, and environmental contamination effects. Specific objectives are to: (1) compare four coatings across four ceramic tiles and three shoe types; (2) assess arid, damp, and foamy environmental impacts; and (3) identify optimal combinations for walkway safety per ANSI A137.1:2022 and ISO 5436:2021 standards.

methodsFour coating materials (CM 1-CM 4) were applied to four ceramic tile surfaces (CT 1-CT 4) and evaluated using tribological testing under arid, damp, and foamy contamination conditions with three footwear materials. Surface texture parameters were characterised using roughness measurements, and dynamic friction coefficients (DFCs) were determined through controlled dynamic friction tests. A nonlinear predictive model incorporating coating material performance (CMP), surface texture modification (STM), and environmental factors (E) was developed and validated using statistical analysis and cross-validation across 144 experimental combinations (432 individual measurements).

resultsTexCoMP achieved a mean absolute error (MAE) of 0.03, a root mean square error (RMSE) of 0.04, a Pearson correlation (R) of 0.92, and an R2 of 0.93, outperforming linear models by 22% in terms of RMSE under foamy conditions. The epoxy-CT4 pairing yielded a DFC of 0.62 ± 0.03 in damp conditions, 24% above the OSHA safety threshold of 0.5, indicating substantially reduced slip potential. Four-way ANOVA revealed highly significant interactions (p < 0.001) with environmental condition as the dominant factor (partial η² = 0.47).

conclusionsThe proposed TexCoMP framework provides an interpretable tribological model for predicting slip resistance in coated walkway systems by integrating coating material properties, surface texture modification, and environmental contamination effects. The results demonstrate that coatings incorporating texture-enhancing particles can significantly improve friction performance under damp conditions. TexCoMP therefore offers a practical analytical tool for guiding coating selection and surface engineering strategies to reduce slip-related risks in built environments.

Indexed as

CeramicsModels, TheoreticalFrictionMaterials TestingShoesSurface Properties

Identifiers

PMID42296098
PMCPMC13268189

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.