Observational studyEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2026
Under pressure - a sensor-based analysis of simulated prehospital pressure dressing application for hemorrhage management.
Observational study in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe concept of "x-ABCDE", with "X" representing exsanguinating hemorrhage, highlights the priority of immediate bleeding control in trauma care. Despite being a fundamental intervention, pressure dressing techniques lack standardization. Studies show high variability in achieved pressures, often below therapeutic targets or exceeding harmful levels, with no correlation between subjective estimates and objective measurements.
objectivesTo objectively assess current practices of pressure bandage application and identify influencing factors including material type, technique, and provider experience.
methodsThis prospective, single-center, simulation-based observational study was conducted from August 2024 to January 2025 at a Level I Trauma Center. Emergency medical providers applied pressure dressings according to personal preference using available materials. Pressure distribution was measured via two calibrated capacitive pressure sensors (61 measurement fields). Analysis included correlation tests, group comparisons, and multiple regression.
resultsA total of 124 emergency medical providers (75% male; 36% paramedics, 44% emergency medical technicians, 13% trainees, 7% emergency physicians) completed pressure dressing applications, with 116 datasets included in final analysis. Mean maximum pressure was 169.35 ± 84.33 mmHg (range 50-412 mmHg) with application duration of 51.20 ± 18.14 s. Emergency physicians generated significantly higher pressures than non-physician groups (p < 0.001). The short-tug technique was the strongest predictor of maximum pressure (p < 0.001), followed by bandage material. Israeli bandages achieved highest pressures (205.40 ± 98.12 mmHg), followed by medium-stretch (171.68 ± 75.03 mmHg) and elastic fixation bandages (135.50 ± 58.63 mmHg). Excessive pressures > 250 mmHg occurred in 28% of Israeli bandage applications versus 11.1% for medium-stretch and 1.6% for elastic bandages. Pressure distribution showed volar focusing with highest values measured by the smaller sensor in the central area, best achieved through medium-stretch bandages. No correlation was found between subjective self-assessment and objective pressure measurements (p = 0.541).
conclusionsPressure dressing application varies significantly by material, technique, and experience. While the short-tug technique and Israeli bandages achieved highest peak pressures, medium-stretch bandages demonstrated the most therapeutically consistent pressure distribution, with pronounced target pressure focusing and the lowest rate of excessive pressures within the present observational simulation setting. Lack of correlation between self-assessment and objective performance highlights the need for standardized training protocols and evidence-based technique guidelines.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.