Evidence map›Paper›PMID 42293190›Full record

ArticleFrontiers in nutrition2026

Evaluating the agreement of continuous glucose monitoring system with venous methods for glycemic index determination.

Lihua Li, Qiaosheng Hu, Menglan Li, Yan Zhao, Rui Zhang, Yan Liu, Xin Tong, Haiying Zhu, Mengya Zhang, Qing Zhao and 1 more

Abstract read
In one paragraph

Article in Frontiers in nutrition, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Lihua Li *Lianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China.
Qiaosheng Hu *Lianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China.
Menglan LiLianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China.
Yan ZhaoJiangsu Province People's Hospital, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu, China.
Rui ZhangLianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China.
Yan LiuLianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China.
Xin TongLianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China.
Haiying ZhuLianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China.
Mengya ZhangLianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China.
Qing ZhaoLianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China.
Xianghua MaJiangsu Province People's Hospital, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Continuous glucose monitoring systems (CGMS) are widely used in diabetes care, but their reliability for standardized food glycemic index (GI) measurement remains unclear. Most previous studies used capillary blood rather than venous glucose as the reference. Objective: This study aimed to verify the consistency between the CGMS and standardized venous sampling methods for measuring postprandial incremental area under the curve (IAUC) and GI values. Methods: This study was conducted in accordance with the Chinese GI testing standard WS/T 652-2019. Three measurement methods were compared: venous sampling (Method A), CGMS with all data points adopted (Method B), and CGMS data aligned with the standard venous time points (Method C). One-way analysis of variance (ANOVA) and Lin's concordance correlation coefficient (CCC) were used for statistical analysis. The Parkes Error Grid analysis was employed to ascertain the clinical acceptability of glucose discrepancies within low, medium, and high concentration strata. Results: The 12 enrolled participants (six males and six females) had a mean age of 29.50 ± 10.12 years, mean BMI of 21.5 ± 1.7 kg/m Conclusion: CGMS methods demonstrate good-to-moderate concordance with standardized venous testing for IAUC and GI determination. CGMS may represent a feasible, non-invasive alternative for food GI evaluation in nutritional and diabetes-related research among healthy individuals.

Indexed as

continuous glucose monitoring systemglycemic indexincremental area under the curveLin’s concordance correlation coefficientParkes error grid

Identifiers

PMID42293190
PMCPMC13253292

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.