Strong correlation between phantomless and inline phantom-based densitometric calibration of vertebral properties from CT scans of healthy volunteers.

Fiona G Gibson, Zichu Ding, Margaret A Paggiosi, Catherine Handforth, Janet E Brown, Xinshan Li, Enrico Dall'Ara, Stefaan W Verbruggen

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Fiona G GibsonSchool of Mechanical, Aerospace and Civil Engineering, The University of Sheffield, Sheffield, United Kingdom.
Zichu DingCentre for Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, United Kingdom.
Margaret A PaggiosiDivision of Clinical Medicine, School of Medicine and Population Health, The University of Sheffield, Sheffield, United Kingdom.
Catherine HandforthDivision of Clinical Medicine, School of Medicine and Population Health, The University of Sheffield, Sheffield, United Kingdom.
Janet E BrownDivision of Clinical Medicine, School of Medicine and Population Health, The University of Sheffield, Sheffield, United Kingdom.
Xinshan LiSchool of Mechanical, Aerospace and Civil Engineering, The University of Sheffield, Sheffield, United Kingdom.
Enrico Dall'AraInsigneo Institute, The University of Sheffield, Sheffield, United Kingdom.
Stefaan W VerbruggenSchool of Mechanical, Aerospace and Civil Engineering, The University of Sheffield, Sheffield, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Phantom calibration is currently the gold standard for calibrating CT scans and for calculating material properties of dense tissues for computational models. However, in Oncology departments and low-resource settings, it is not routine to include a calibration phantom within the scanning protocol. Therefore, retrospective scan datasets are challenging to calibrate for biomechanical investigations, precluding detailed measurements of material and mechanical properties. In this study, we compared the results from a phantomless calibration technique, where the density within each scan was independently calibrated based on known tissue densities captured within each scan (e.g., air), with those from a traditional inline phantom calibration. To do so we used scans from a cohort of healthy volunteers from the control arm of a clinical trial dataset (ANTELOPE) in which inline calibration phantoms were included. We found that, when selecting air and the aorta as regions for calibration within individual CT scans, a strong individual-specific correlation existed between bone mineral density measured in the phantomless and phantom calibrations. This indicates that the phantomless calibration method can be a useful and reliable tool for quantifying the densitometric material properties of healthy human vertebrae, and provides the opportunity for further analysis of spinal CT scans in either retrospective datasets or in low-resource clinical settings.

Indexed as

BMDbone mineral densityCT scanphantomless calibrationvertebral biomechanics

Identifiers

PMID42292525
PMCPMC13260149

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.