Strong correlation between phantomless and inline phantom-based densitometric calibration of vertebral properties from CT scans of healthy volunteers.
Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Phantom calibration is currently the gold standard for calibrating CT scans and for calculating material properties of dense tissues for computational models. However, in Oncology departments and low-resource settings, it is not routine to include a calibration phantom within the scanning protocol. Therefore, retrospective scan datasets are challenging to calibrate for biomechanical investigations, precluding detailed measurements of material and mechanical properties. In this study, we compared the results from a phantomless calibration technique, where the density within each scan was independently calibrated based on known tissue densities captured within each scan (e.g., air), with those from a traditional inline phantom calibration. To do so we used scans from a cohort of healthy volunteers from the control arm of a clinical trial dataset (ANTELOPE) in which inline calibration phantoms were included. We found that, when selecting air and the aorta as regions for calibration within individual CT scans, a strong individual-specific correlation existed between bone mineral density measured in the phantomless and phantom calibrations. This indicates that the phantomless calibration method can be a useful and reliable tool for quantifying the densitometric material properties of healthy human vertebrae, and provides the opportunity for further analysis of spinal CT scans in either retrospective datasets or in low-resource clinical settings.