Evidence map›Paper›PMID 42292293›Full record

ArticleBioactive materials2026

In-situ Damascus-patterning enables tunable surface electric fields for bioactive titanium implants.

Hanyang Yu, Nan Hou, Subrahmanyam Pattamatta, Sien Lin, Shi-Ting Chen, Weixi Wu, Fenghui Duan, Youneng Xie, Xuliang Chen, Yunchen Long and 9 more

Abstract read
In one paragraph

Article in Bioactive materials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

19 authors.

Hanyang YuDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.
Nan HouMusculoskeletal Research Laboratory, Department of Orthopaedics & Traumatology, Faculty of Medicine, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong, China.
Subrahmanyam PattamattaDepartment of Mechanical Engineering, The University of Hong Kong, Hong Kong, China.
Sien LinDepartment of Orthopaedics & Traumatology, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, China.
Shi-Ting ChenDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.
Weixi WuDepartment of Physics, City University of Hong Kong, Hong Kong, China.
Fenghui DuanDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.
Youneng XieDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.
Xuliang ChenDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.
Yunchen LongDepartment of Materials Science and Engineering, City University of Hong Kong, Hong Kong, China.
Gan LiDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.
Yuhan ChenDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.
Siyao ChenDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.
Yicheng HanDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.
Xiaojiao YouDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.
Zhuoyuan LiDepartment of Mechanical Engineering, The University of Hong Kong, Hong Kong, China.
Yu ChaiDepartment of Physics, City University of Hong Kong, Hong Kong, China.
Gang LiCenter for Locomotor System Regenerative Medicine and Technology, Institute of Biomedicine and Biotechnology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, China.
Jian LuDepartment of Mechanical Engineering, City University of Hong Kong, Hong Kong, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Conventional titanium implants, although biocompatible, are inherently bioinert and typically require complex surface modifications to achieve satisfactory osseointegration. Here, we report a new additive manufacturing strategy that directly imparts bioactivity to high-performance titanium-tantalum implants (elastic modulus: 60-80 GPa; strength: >1100 MPa) through in situ compositional modulation, and this functionality is retained after subsequent subtractive processing. By precisely regulating the extent to which tantalum melts into the titanium matrix during laser powder bed fusion, periodic Damascus-like compositional patterns are generated that, after simple oxidation, produce stable periodic surface potential differences (P-SPD) tunable from 5.59 to 48.01 mV, spanning the range observed in natural tissues. The resulting electric field (∼2.35 V/m) also lies within the biologically active range used in external stimulation studies to promote osteogenesis, directed migration, and neural responses. The resulting endogenous electric field nearly doubles osteogenic performance relative to Ti64ELI controls, as evidenced by both in vitro assays and in vivo cranial defect repair. Mechanistic studies further reveal that P-SPD promotes both cell migration and osteogenic differentiation. This work establishes a strategy for the in situ integration of structural and biological functions through controlled melting behavior, offering a new paradigm for the surface functionalization of bioimplants.

Indexed as

Additive manufactureEndogenous electric fieldOsseointegrationSpontaneous polarizationStructure-function integration

Identifiers

PMID42292293
PMCPMC13264130

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.