ArticleResuscitation plus2026
Physiological changes after deflation of Resuscitative Endovascular Balloon Occlusion of the Aorta following Automated Head-up Position Cardiopulmonary Resuscitation: a post-hoc analysis.
Article in Resuscitation plus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Use of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) and the automated head-up position (AHUP) have increasingly both been separately reported during cardiopulmonary resuscitation (CPR). The optimal hemodynamic management of REBOA balloon deflation after the return of spontaneous circulation (ROSC) is unknown. We hypothesized that partial deflation of REBOA rather than full deflation after ROSC would result in better hemodynamic parameters. Methods: After 10 min of untreated ventricular fibrillation, AHUP-CPR was performed on 20 pigs (weighting ∼40 kg). After 36 min, a REBOA balloon was inflated. After ROSC (13 pigs) REBOA deflation was initiated in one of two ways: complete (100%) or partial (50%) deflation. The primary endpoint was mean difference in mean aortic pressure (MAP) compared one minute before and one minute after REBOA deflation. Secondary endpoints were mean difference in cerebral perfusion (CerPP) and coronary perfusion (CorPP) pressures (in mmHg). Data were compared using Mann-Whitney Results: After ROSC the mean difference in MAP before and after deflation was 38.5 mmHg (95%CI: 17.0-60.0) with complete deflation versus 7.0 (95%CI: 1.8-12.3) with partial deflation ( Conclusion: In this porcine model of prolonged AHUP-CPR, partial REBOA balloon deflation resulted in superior hemodynamics compared with complete deflation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.