Evidence map›Paper›PMID 42288855›Full record

ArticleBMC biotechnology2026

Au-IDE/LFA biosensor: an integrated sensing platform with lateral flow immunoassay for quantitative detection of hCG hormone using non-faradaic continuous FFT-admittance voltammetry.

Nazanin Behrooz, Farzaneh Shemirani, Reza Faridi-Majidi

Abstract read
In one paragraph

Article in BMC biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Nazanin BehroozCenter of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, Iran.
Farzaneh ShemiraniSchool of Chemistry, College of Science, University of Tehran, Tehran, Iran. fashemirani@ut.ac.ir.
Reza Faridi-MajidiDepartment of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran. refaridi@sina.tums.ac.ir.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The development of the novel Au-IDE/LFA (gold interdigitated electrode with lateral flow immunoassay) biosensor, an integrated electrochemical sensing platform with lateral flow immunoassay, for quantitative detection of hCG (human Chorionic Gonadotropin) hormone levels is successfully directed here. To fabricate the Au-IDE/LFA setup, a free multi-electrode array of AU-IDE was configured exactly on five zones of LFA on the flow direction, employing non-faradaic measurements through a combination of two electrodes. The impedance behavior of each zone, connected with an Au surface electrode in the Au-IDE/LFA setup was characterized by frequency response analysis (FRA) using non-faradaic electrochemical impedance spectroscopy. Precisely, FRA validated that Au surfaces exhibit similar current homogeneity due to produce the repeatable impedance. The assay optimization using CFFT (Continuous Fast Fourier Transform)-admittance voltammetry, a new method, pinpointed that optimizing the excitation potential by utilizing lower SW frequencies at 88 Hz, amplitude at 10 mV, and DC potential at 10 mV resulted in excellent admittance responses of Au-IDE/LFA biosensor. Both bare and standard LFA were used for signal baseline establishment to ignore the background signal noise induced by the anti-β-hCG-AuNPs (6.01 µA/V), PBS buffer (11.51 µA/V), and urine background (22.11 µA/V). Admittance response showed a high sensitivity about three times more than impedance response with limit of detection by 2.53 mIU/mL in a linear range of 5-500 mIU/mL for hCG with R

Indexed as

Biosensing TechniquesChorionic GonadotropinElectrochemical TechniquesGoldElectrodesFourier AnalysisHumansImmunoassayChorionic GonadotropinGoldFFT-admittance voltammetryFrequency response analysishCG (human Chorionic Gonadotropin)ImpedanceIntegrated sensing platformLateral flow immunoassayNon-faradaic electrochemical sensor

Identifiers

PMID42288855
PMCPMC13491876

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.