Evidence map›Paper›PMID 42287486›Full record

ArticleJournal of materials science. Materials in medicine2026

Comparative hemocompatibility assessment of fibrin/heparin-coated and PMEA-coated flow diverters.

Huan Wei, Tomáš Riedel, Zuzana Riedelová, Melanie Wolf, Christian Schlensak, Meltem Avci-Adali

Abstract readComparative Study
In one paragraph

Article in Journal of materials science. Materials in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Huan WeiDepartment of Thoracic and Cardiovascular Surgery, University Hospital Tuebingen, Tuebingen, Germany.
Tomáš RiedelDepartment of Chemistry and Physics of Surfaces and Biointerfaces, Institute of Macromolecular Chemistry, Czech Academy of Sciences, Prague 6, Czechia.
Zuzana RiedelováDepartment of Chemistry and Physics of Surfaces and Biointerfaces, Institute of Macromolecular Chemistry, Czech Academy of Sciences, Prague 6, Czechia.
Melanie WolfDepartment of Thoracic and Cardiovascular Surgery, University Hospital Tuebingen, Tuebingen, Germany.
Christian SchlensakDepartment of Thoracic and Cardiovascular Surgery, University Hospital Tuebingen, Tuebingen, Germany.
Meltem Avci-AdaliDepartment of Thoracic and Cardiovascular Surgery, University Hospital Tuebingen, Tuebingen, Germany. meltem.avci-adali@uni-tuebingen.de.ORCID http://orcid.org/0000-0003-4008-4272

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Flow diverters play an important role in the endovascular treatment of intracranial aneurysms; however, their use can be associated with thromboembolic complications. Thus, in recent years, flow diverters with surface coatings have been developed to prevent thrombus-related complications. In this study, the hemocompatibility of the flow diverters FRED X with poly(2-methoxyethyl acrylate) (PMEA) coating and the DERIVO 2heal with fibrin/heparin coating, as well as the uncoated DERIVO 2 flow diverter, was evaluated using an in vitro blood circulation model. Using enzyme-linked immunosorbent assay (ELISA), biomarkers of thrombocytes (β-thromboglobulin (β-TG)), coagulation (thrombin-antithrombin complex (TAT)), complement system (SC5b-9), and inflammation (PMN elastase) activation were analyzed. Further analyses comprised thrombogenicity assessment by scanning electron microscopy and measurement of blood cell counts and hemolysis. The uncoated DERIVO 2 flow diverter exhibited increased coagulation and platelet activation, accompanied by enhanced adhesion of platelets to the blood-contacting surfaces. In contrast, both the FRED X and the DERIVO 2-heal flow diverter could effectively reduce the coagulation (TAT) and platelet activation (β-TG) and prevent the adhesion of platelets. Notably, DERIVO 2heal flow diverter induced significantly lower activation of the complement system (SC5b-9) and reduced inflammatory response (PMN elastase) compared to FRED X flow diverter. These findings indicate the improved hemocompatibility of the fibrin/heparin-coated DERIVO 2heal flow diverter and its potential to reduce thromboinflammatory complications.

Indexed as

AcrylatesCoated Materials, BiocompatibleFibrinHeparinPolymersAntithrombin IIIbeta-ThromboglobulinBlood CoagulationBlood PlateletsHemolysisHumansMaterials TestingMicroscopy, Electron, ScanningPeptide HydrolasesPlatelet ActivationThrombosisAcrylatesAntithrombin IIIantithrombin III-protease complexbeta-ThromboglobulinCoated Materials, BiocompatibleFibrinHeparinPeptide Hydrolasespoly(2-methoxyethylacrylate)Polymers

Identifiers

PMID42287486
PMCPMC13264555

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.