Evidence map›Paper›PMID 42287342›Full record

ArticleMikrochimica acta2026

Development of an ligase chain reaction-fluorescence-SERS multimodal biosensing workflow for ultrasensitive detection and single-base discrimination of KRAS ctDNA.

Sohila Mostafa, Dilek Kanarya, Khwanchai Tantiwanichapan, Raju Botta, Pitak Eiamchai, Pacharamon Somboonsaksri, Nimet Yıldırım Tirgil

Abstract read
In one paragraph

Article in Mikrochimica acta, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sohila MostafaDepartment of Biomedical Engineering, Ankara Yıldırım Beyazıt University, Ankara, Türkiye.
Dilek KanaryaDepartment of Biomedical Engineering, Ankara Yıldırım Beyazıt University, Ankara, Türkiye.
Khwanchai TantiwanichapanNational Electronics and Computer Technology Center (NECTEC), National Science and Technology Development Agency (NSTDA), 112, Khlong Nueng, Khlong Luang, Pathum Thani, 12120, Thailand.
Raju BottaNational Electronics and Computer Technology Center (NECTEC), National Science and Technology Development Agency (NSTDA), 112, Khlong Nueng, Khlong Luang, Pathum Thani, 12120, Thailand.
Pitak EiamchaiNational Electronics and Computer Technology Center (NECTEC), National Science and Technology Development Agency (NSTDA), 112, Khlong Nueng, Khlong Luang, Pathum Thani, 12120, Thailand.
Pacharamon SomboonsaksriNational Electronics and Computer Technology Center (NECTEC), National Science and Technology Development Agency (NSTDA), 112, Khlong Nueng, Khlong Luang, Pathum Thani, 12120, Thailand.
Nimet Yıldırım TirgilDepartment of Biomedical Engineering, Ankara Yıldırım Beyazıt University, Ankara, Türkiye. nyildirim.tirgil@aybu.edu.tr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A dual-modality biosensing platform integrating ligase chain reaction (LCR), fluorescence monitoring, and surface-enhanced Raman scattering (SERS) was developed. The LCR step ensures high-fidelity enzymatic amplification, enabling precise discrimination of single-base mismatches at the KRAS locus. Real-time fluorescence using 20 nm gold magnetic nanoparticles provides rapid quantitative evaluation, while SERS analysis on nanostructured OnSpec-Lite bimetallic chips offers molecular-fingerprint confirmation. Under optimized conditions (30 cycles, 60 °C), the biosensor achieved a calculated limit of detection (LOD) of 1.03 fM for SERS and 11.94 fM for fluorescence detection, with corresponding limits of quantification (LOQ) of 3.12 fM and 36.17 fM, respectively. Derived from the linear regression of the SERS calibration curve (y = 73.77x + 871.1; R2 = 0.9617), a linear concentration range of 1 pM to 1000 nM was obtained. Meanwhile, the fluorescence calibration yielded a linear range of 100 pM to 1000 nM (y = 0.069x + 4.848; R2 = 0.8705). Experimentally, the lowest validated ctDNA concentrations detected were 1 pM for SERS and 100 pM for fluorescence. Both detection systems demonstrated high reproducibility, with relative standard deviations (RSDs) below 10%. Furthermore, the platforms maintained analytical robustness in 1/10 and 1/5 serum dilutions, successfully mitigating matrix interference while preserving distinctive Raman signatures. This study introduces a proof-of-concept analytical framework that bridges the high specificity of enzymatic ligation with the ultra-sensitive transduction of nanoplasmonic detection. By combining real-time optical quantification with confirmatory vibrational spectroscopy, the system minimizes false positives and provides cross-validated results essential for high-stakes diagnostics.

Indexed as

Biosensing TechniquesCirculating Tumor DNALigase Chain ReactionProto-Oncogene Proteins p21(ras)FluorescenceGoldHumansLimit of DetectionMetal NanoparticlesSpectrometry, FluorescenceSpectrum Analysis, RamanCirculating Tumor DNAGoldKRAS protein, humanProto-Oncogene Proteins p21(ras)BiosensorCirculating tumor DNA (ctDNA)Fluorescence monitoringLigase chain reaction (LCR)Surface-enhanced Raman scattering (SERS)

Identifiers

PMID42287342
PMCPMC13264572

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked