Evidence map›Paper›PMID 42286615›Full record

ArticleBMC oral health2026

Balancing radiopacity and artifact generation: a quantitative evaluation of CBCT artifacts induced by resin-based restorative materials.

İkbal Esra Pehlivan, Sema Kaya, Alaettin Koç

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

İkbal Esra PehlivanDepartment of Restorative Dentistry, Faculty of Dentistry, Van Yuzuncu Yıl University, Van, Turkey. ikbalpehlivan@yyu.edu.tr.ORCID 0000-0002-3266-7657
Sema KayaDepartment of Oral and Maxillofacial Radiology, Faculty of Dentistry, Van Yuzuncu Yıl University, Van, Turkey.ORCID 0000-0002-6306-3901
Alaettin KoçDepartment of Oral and Maxillofacial Radiology, Faculty of Dentistry, Van Yuzuncu Yıl University, Van, Turkey.ORCID 0000-0001-9984-6900

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhile metal-induced artifacts in cone-beam computed tomography (CBCT) are well documented, quantitative data regarding the artifact intensity and spatial distribution of modern injectable composites compared with conventional resin-based materials are sparse. This in vitro study quantitatively evaluated and compared beam-hardening and blooming artifacts generated by various resin-based restorative materials, specifically investigating whether modern injectable composites produce different artifact profiles than conventional resins in CBCT imaging.

methodsNinety 3D-printed mandibular canine models with standardized distal cavities were restored using six different materials (n = 15 per group): G-ænial Anterior (GA), EQUIA Forte HT Fil (EQF), G-ænial Universal Injectable (GUI), Vittra APS Unique (VAU), Charisma Diamond ONE (CHR), and OMNICHROMA (OMN). All samples were scanned using a CS 9600 CBCT unit under identical exposure parameters (120 kV, 4.0 mA, 0.15 mm voxel size) to eliminate motion artifacts and ensure standardization. Grayscale values (GV) were measured on mesial, distal, buccal, and lingual surfaces using standardized regions of interest (ROIs) positioned adjacent to the restoration. Statistical analyses were performed using one-way ANOVA and Kruskal-Wallis tests with post-hoc corrections (α = 0.05).

resultsSignificant differences in GV were observed on the mesial (p < 0.001), distal (p < 0.001), and buccal (p = 0.004) surfaces, whereas no significant difference was found on the lingual surface (p = 0.053). The GUI and GA groups showed the highest GV, while CHR exhibited the lowest GV across all surfaces. The highest GV were recorded on the mesial surface, not on the distal surface where the restoration was placed (p < 0.001).

conclusionsDifferent resin-based restorative materials produced different grayscale values and artifact patterns under standardized CBCT conditions. The high-filler injectable composite showed artifact characteristics comparable to those of high-viscosity resin-based materials, particularly on the surface opposite to the restoration. These findings suggest that material-related factors may influence CBCT artifact expression; however, because no direct chemical or elemental analysis was performed, these interpretations should be made cautiously. In clinical situations where CBCT imaging is anticipated, clinicians should consider the potential effect of restorative material radiopacity on image interpretation while balancing the diagnostic need for radiopaque restorations in conventional radiography.

Indexed as

ArtifactsComposite ResinsCone-Beam Computed TomographyDental MaterialsDental Restoration, PermanentCuspidHumansModels, DentalComposite ResinsDental MaterialsArtifactsCone-beam computed tomographyDental materialsDental restorationsIn vitro studyRadiopacity

Identifiers

PMID42286615
PMCPMC13487998

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.