Evidence map›Paper›PMID 42286401›Full record

ArticleSports medicine - open2026

Pulse Rate Variability Is Not the Same as Heart Rate Variability: Implications for Sports Performance and Injury Prevention.

Kfir Ben-David, Allen B Kantrowitz, Michael Morris, Eric J Renaghan, Luis A Feigenbaum, Kyle Bellamy, Joe Girardi, Harrison L Wittels, Michael J Wishon, Samantha M McDonald and 1 more

Abstract read
In one paragraph

Article in Sports medicine - open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Kfir Ben-David *Department of Surgery, Mount Sinai Medical Center, Miami Beach, FL, 33140, USA.
Allen B Kantrowitz *Department of Neurosurgery, Mount Sinai Medical Center, Miami Beach, FL, 33140, USA.
Michael MorrisDepartment of Pulmonology, Brooke Army Medical Center, Fort Sam, Houston, TX, 78234, USA.
Eric J RenaghanDepartment of Athletics, Sports Science, University of Miami, Miami, FL, 33140, USA.
Luis A FeigenbaumDepartment of Physical Therapy, Miller School of Medicine, University of Miami, Miami, FL, 3140, USA.
Kyle BellamyDepartment of Athletics, Nutrition, University of Miami, Miami, FL, 33140, USA.
Joe GirardiDepartment of Sports Medicine, Texas A&M, College Station, TX, 77834, USA.
Harrison L WittelsTiger Tech Solutions, Inc., Miami, FL, 33140, USA. research@tigertech.solutions.
Michael J WishonTiger Tech Solutions, Inc., Miami, FL, 33140, USA.
Samantha M McDonaldTiger Tech Solutions, Inc., Miami, FL, 33140, USA.
S Howard WittelsTiger Tech Solutions, Inc., Miami, FL, 33140, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA key metric utilized by coaches and athletes to track athlete performance is heart rate variability (HRV). HRV calculated via electrocardiogram (ECG) has been shown to track autonomic function. However, many wearable devices utilize photoplethysmography (PPG) to calculate pulse rate variability (PRV). Our study investigated the agreement between PRV and HRV in a beat-to-beat analysis in a sample of American football players. Data from 103 male, Division I collegiate American football athletes, collected over three seasons, were analyzed. Heart rate (HR), pulse rate (PR), and two time-domain indices for PRV/HRV were measured (rMSSD and SDNN). Agreement between PRV and HRV was assessed using Bland-Altman analysis (bias, limits of agreement, and confidence intervals) with supporting error metrics (MAE, RMSE, Pearson r, and Lin's concordance correlation coefficient). To evaluate whether PRV detected autonomic deviations of the same magnitude to HRV on the same day, a sliding-window z-score threshold-crossing analysis (0.5-2.0 SD) quantified PRV detection rates and PRV delay.

resultsHR and PR were similar at (59.4 (10.3) bpm vs. 59.7 (10.3) bpm). In contrast, PPG-PRV values were lower than ECG-HRV for both rMSSD and SDNN (80.9 (23.1) ms vs. 103.9 (22.0) ms, 141.3 (41.7) ms vs. 167.9 (40.0) ms). Bland-Altman analysis showed negative bias for rMSSD and SDNN across PPG wavelengths, race, and obesity, while HR/PR agreement was high with small bias (0.24-0.44 bpm). In the deviation analysis, PRV detected fewer autonomic deterioration events on the same day as HRV, capturing 16.7% to 56.7% of HRV-identified rMSSD events and 16.8%-52.0% of SDNN events across thresholds, and exhibited an average delay of 1.8-5.5 days in detecting changes already identified by ECG-HRV.

conclusionsOur findings refute PPG-PRV as an equivalent surrogate for ECG-HRV for tracking autonomic function over time. Specifically, the delay in response when using PPG-PRV to track athlete autonomic function will result in missed opportunities for coaches to prevent autonomic deterioration. Finally, the PRV calculated with PPG should not be called HRV as it confuses scientists and consumers.

Indexed as

American footballAthletesAutonomic nervous systemElectrocardiographyPhotoplethysmographyWearable technology

Identifiers

PMID42286401
PMCPMC13263368

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.