ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026
Polymer-Based Multiparameter Sensing Integrated Photonic Chip for Health Monitoring.
Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
Optical sensors are essential in medical diagnostics and detect variations in light intensity, phase, wavelength, polarization, or interference. However, conventional devices face limitations in multiplexing capability, surface functionalization, and integration. Here, we propose a monolithic integrated poly(dimethylsiloxane) (PDMS)/poly(methyl methacrylate) (PMMA) photonic chip that monolithically integrates two photonic waveguide Bragg grating (WBG) blood glucose sensors, a photonic WBG pressure sensor array, four photonic WBG temperature sensors, a photonic Mach-Zehnder modulator (MZM) electrocardiogram (ECG) sensor, and a photonic Mach-Zehnder interferometer (MZI) sweat glucose sensor, together with an on-chip arrayed waveguide grating (AWG) demodulation unit. The experimental results demonstrate that the WBG glucose sensor operates stably from 0 to 2.3 mg/mL, the pressure sensor from 0 to 12 kPa, and the temperature sensor from 35 to 41°C. The MZM ECG sensor achieves a half-wave voltage of 1.6 V, with performance comparable to that of commercial systems. The MZI sweat glucose sensor offers a detection range of 0-0.2 mg/mL, a sensitivity of approximately 9.3595 mW/(mg/mL), and high linearity. With a miniature footprint of approximately 1 cm × 0.5 cm, this work offers a robust on-chip multiparameter sensing solution, paving the way for next-generation wearable continuous health monitoring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.