Evidence map›Paper›PMID 42284278›Full record

ArticleMedical physics2026

Sinogram-based flow estimation in computed tomography using a physics-informed neural network: Impact of gantry rotation speed, X-ray fluence and pulsed acquisition on accuracy.

Jinyuxuan Guo, Gurnoor Singh Khurana, Alejandro Gonzalo Grande, Juan C Del Alamo, Francisco Contijoch

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jinyuxuan GuoDepartment of Bioengineering, University of California San Diego, La Jolla, California, USA.
Gurnoor Singh KhuranaDepartment of Computer Science Engineering, University of California San Diego, La Jolla, California, USA.
Alejandro Gonzalo GrandeDepartment of Mechanical Engineering, University of Washington, Seattle, Washington, USA.
Juan C Del AlamoDepartment of Mechanical Engineering and Cardiology, University of Washington, Seattle, Washington, USA.
Francisco ContijochDepartment of Bioengineering, University of California San Diego, La Jolla, California, USA.

Funding

Patient-specific thrombosis risk in atrial fibrillation by 4D CT imaging of atrial kinetics combined with computational fluid dynamicsR01HL160024 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DEL ALAMO, JUAN CARLOS, KAHN, ANDREW · 2021 to 2024
$2.7M
Comprehensive Assessment of Right Ventricular and Pulmonary Vascular Function via CT Imaging in Heart Failure PatientsK01HL143113 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI CONTIJOCH, FRANCISCO J · 2018 to 2022
$872k
NHLBI NIH HHS K01 HL143113NHLBI NIH HHS R01 HL160024US National Institutes of Health, National Heart, Lung, and Blood Institute K01HL143113US National Institutes of Health, National Heart, Lung, and Blood Institute R01HL160024
6 · The paper itself

Abstract

backgroundNon-invasive imaging-based assessment of blood flow plays a critical role in evaluating heart function and structure. Computed Tomography (CT) is a widely-used imaging modality that can robustly evaluate cardiovascular anatomy and function, but direct methods to estimate blood flow velocity from movies of contrast dynamics have not been developed. PURPOSE: This study evaluates the impact of CT imaging parameters on Physics-Informed Neural Networks (PINN)-based flow estimation and proposes an improved PINN-based approach, SinoFlow, which uses sinogram data directly to estimate blood flow.

methodsWe generated pulsatile flow fields in an idealized 2D vessel bifurcation using computational fluid dynamics and simulated CT scans with varying gantry rotation speeds, photon flux, and pulse mode imaging settings. We compared the performance of PINN-based flow estimation using reconstructed images (ImageFlow) to SinoFlow.

resultsSinoFlow significantly improved flow estimation performance by avoiding temporal inconsistency errors introduced by filtered backprojection. SinoFlow was robust across all tested gantry rotation speeds and consistently produced lower mean squared error and velocity errors than ImageFlow. Additionally, SinoFlow was less susceptible to noise in the sinogram and was compatible with pulsed-mode imaging and maintained higher accuracy with shorter pulse widths.

conclusionsThis study demonstrates the potential of SinoFlow for CT-based flow estimation, providing a more promising approach for non-invasive blood flow assessment. The findings inform future applications of PINNs to CT images and provide an alternative which avoids limitations associated with image-based estimation.

Indexed as

Image Processing, Computer-AssistedNeural Networks, ComputerPhysicsTomography, X-Ray ComputedBlood Flow VelocityHydrodynamicsRotationX-Rayscomputed tomographyflow velocimetryphysics‐informed neural networks

Identifiers

PMID42284278
PMCPMC13262815

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.