ArticleSensors (Basel, Switzerland)2026
A Coarse-to-Fine Framework for Oil-Water Interface Measurement in Small-Caliber Transparent Test Tubes.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Accurate oil-water interface measurement in small transparent test tubes is important for subsequent volume readout in laboratory analysis. However, manual observation and conventional vision-based methods are easily affected by illumination variation, wall stains, and bubbles, while deep learning detectors alone usually provide only coarse semantic perception. To address this issue, a coarse-to-fine framework is proposed for robust oil-water interface measurement. In the coarse stage, YOLOv8n is used to provide semantic constraints for subsequent processing. In the fine stage, a Fisher-discriminative chromatic-weighted brightness feature is constructed from RGB information, where the RGB weights are derived from the Fisher criterion to enhance oil-water chromatic separability rather than using fixed grayscale or empirical channel weights. This feature is then fused with a SobelY-based vertical-gradient feature to improve interface localization. A stain-aware row-aggregation strategy with effective-pixel compensation is further introduced to suppress artefact interference. The validated interface position is finally converted into a volume readout, with additional correction for bubble-induced bias. The framework was validated on sampled frames from a complete shale-oil core pressing process conducted under mixed-lighting conditions. Stage-wise evaluation and ablation results indicate that the proposed design improves readout stability under stains, bubbles, and illumination variation, achieving a mean absolute error of 0.0159 mL and keeping the maximum error below 0.03 mL in the current experimental setup.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.