Evidence map›Paper›PMID 42281024›Full record

ArticleSensors (Basel, Switzerland)2026

A Data-Driven Spatiotemporal Risk Assessment Framework for Transformer Overload in Distributed Renewable Energy System.

Chengjun Xie, Chenhao Sun, Yanzheng Liu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Chengjun XieState Key Laboratory of Disaster Prevention & Reduction for Power Grid, Changsha University of Science and Technology, Changsha 410114, China.
Chenhao SunState Key Laboratory of Disaster Prevention & Reduction for Power Grid, Changsha University of Science and Technology, Changsha 410114, China.ORCID 0000-0002-1661-4555
Yanzheng LiuState Key Laboratory of Disaster Prevention & Reduction for Power Grid, Changsha University of Science and Technology, Changsha 410114, China.

Funding

National Natural Science Foundation of China 52207074Natural Science Foundation of Hunan 2024JJ9167Natural Science Foundation of Hunan 2024JJ9175
6 · The paper itself

Abstract

In distributed renewable energy systems, load fluctuations caused by energy resources and energy storage increase the overload risk of distribution transformers, which may accelerate insulation aging and cause overheating, and undermine operational reliability. For transformer condition monitoring, this risk is reflected not by a single variable but by heterogeneous sensing observations acquired from electrical, thermal, and equipment status monitoring channels. Because full-scale inspection of latent defects is impractical under limited staffing and equipment resources, accurate overload risk prediction is important for sensor-driven maintenance allocation. With such motivations, this paper proposes a Transformer Overload Risk Assessment (TORA) approach for robust overload risk prediction under nonstationary load conditions. First, a feature matrix is constructed by jointly incorporating static features that capture long-term drift and dynamic features extracted from multisource sensing and supervisory signals that reflect short-term fluctuations. Then, static and dynamic features are assessed with Edge-based Static Feature Risk Assessment (E-SFRA) model and Cloud-based Dynamic Feature Risk Assessment (C-DFRA) model, respectively, according to their temporal and statistical characteristics. Next, a periodic calibration model (CE-PAA) is established through a cloud-edge loop, which uses low-latency edge updates and high-capacity cloud computation as feedback. Finally, risk score fusion (RSF) fuses generated static and dynamic risk scores to integrate cloud and edge strengths. The case study results indicate that TORA can transform heterogeneous monitoring signals into calibrated risk information in the studied single power plant scenario, providing useful support for multisource sensor data fusion, transformer condition monitoring, and maintenance decision making. Further validation using multi source field datasets is still needed to assess its cross scenario generalization ability.

Indexed as

cloud-based dynamic feature risk assessmentcloud–edge parameter alignment and adjustmentcondition monitoringedge-based static feature risk assessmentrisk score fusiontransformer overload risk assessment

Identifiers

PMID42281024
PMCPMC13259385

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked