Evidence map›Paper›PMID 42280983›Full record

ArticleSensors (Basel, Switzerland)2026

Non-Contact Blood Pressure Prediction Using Radar with a Lightweight Temporal Multi-Scale Feature Fusion Network.

Yuhan Liu, Tianlin Zhang, Yonggang Luo, Liguo Zhou, Li Ding, Yinwei Li

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuhan LiuSchool of Optoelectronic Information and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Tianlin ZhangSchool of Optoelectronic Information and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Yonggang LuoHenan Medical College, Zhengzhou University, Zhengzhou 450001, China.
Liguo ZhouTerahertz Spectrum and Imaging Technology, Co-Operative Innovation Center, Terahertz Technology Innovation Research Institute, University of Shanghai for Science and Technology, Shanghai 200093, China.
Li DingTerahertz Spectrum and Imaging Technology, Co-Operative Innovation Center, Terahertz Technology Innovation Research Institute, University of Shanghai for Science and Technology, Shanghai 200093, China.ORCID 0000-0001-7438-3057
Yinwei LiTerahertz Spectrum and Imaging Technology, Co-Operative Innovation Center, Terahertz Technology Innovation Research Institute, University of Shanghai for Science and Technology, Shanghai 200093, China.ORCID 0000-0002-0002-186X

Funding

Key Research and Development Program of the Ministry of Science and Technology of China 2023YFF0717900Key Research and Development Program of the Ministry of Science and Technology of China 2023YFF0719200National Natural Science Foundation of China 62588201Natural Science Foundation of Shanghai 21ZR1444300Terahertz Precision Biomedical Technology Discipline Innovation and Intelligence Project D18014
6 · The paper itself

Abstract

Hypertension is a major global health issue, and continuous, convenient blood pressure monitoring is of great significance for early screening and intervention. To address the insufficient exploitation of multi-scale temporal features and the high model complexity in existing radar-based non-contact blood pressure prediction methods, we propose a lightweight temporal multi-scale feature fusion network (LULMNet), for blood pressure prediction and waveform reconstruction. LULMNet adopts a two-stage training strategy. In the first stage, a lightweight one-dimensional U-Net (1D U-Net) is employed for blood pressure waveform reconstruction and intermediate-to-deep temporal feature extraction. In the second stage, systolic and diastolic blood pressure are estimated via multi-scale fusion of intermediate and deep features from the encoder of the 1D U-Net, followed by LSTM-based temporal modeling and regression through a global average pooling (GAP)and a two-layer fully connected prediction head. Experimental results show that the proposed model achieves an error of 3.21 ± 4.94 mmHg for systolic blood pressure (SBP) and 2.25 ± 3.39 mmHg for diastolic blood pressure (DBP), satisfying the Grade A standard of the British Hypertension Society (BHS). In addition, the normalized mean absolute error (NMAE) for waveform reconstruction is as low as 0.044. These results indicate that the proposed method maintains low model complexity while ensuring prediction accuracy, with only 3.0 M parameters and 0.37 G floating-point operations (FLOPs), demonstrating strong potential for non-contact continuous blood pressure monitoring.

Indexed as

Blood PressureBlood Pressure DeterminationRadarAlgorithmsHumansHypertensionNeural Networks, Computerblood pressure predictionhypertensionneural networknon-contact measurementradar

Identifiers

PMID42280983
PMCPMC13259197

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.