ArticleSensors (Basel, Switzerland)2026
Research on Electro-Acoustic Synergistic Partial Discharge Detection Technology for Cable Terminations.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
To address the limited spatial localization accuracy of partial discharge (PD) in high-voltage cable terminations and the difficulty in accurately determining the trigger time in traditional ultrasonic detection, this paper proposes an electro-acoustic synergistic localization technology based on a high-frequency current transformer (HFCT) and a Sagnac optical fiber interferometer. A high-sensitivity Sagnac acoustic sensor based on a 3D-printed photosensitive resin mandrel was developed. Through structural design and 0-50 kHz amplitude-frequency testing, the sensor exhibits a dominant resonant response at 33.2 kHz. This narrow-band, high-sensitivity characteristic effectively enhances the perception capability for weak PD ultrasonic signals. An electro-acoustic synergistic detection system was constructed, in which the high-frequency PD current signal captured by the HFCT was used as the electrical time reference, and a dual-channel Sagnac sensor array was used to extract the arrival times of ultrasonic waves. In a 12 kV laboratory cable-termination PD experiment, the proposed system identified the representative built-in air-gap PD source with an absolute localization error of 5 mm under the tested laboratory configuration. This value should be interpreted as the localization result for the tested representative defect, rather than as a generally validated accuracy specification of the system. This study provides a proof-of-concept laboratory demonstration of an electro-acoustic localization strategy that combines the fast electrical response of HFCT detection with the electromagnetic-interference immunity and acoustic sensitivity of Sagnac fiber-optic sensing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.