ArticleSensors (Basel, Switzerland)2026
Real-Time Transient Voltage and Frequency Sensing Strategy for Resilience Enhancement of PV-Storage Systems in Weak Grids.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Photovoltaic (PV)-storage systems operating in weak grids are affected by high grid impedance, transient voltage disturbances, and measurement noise, which can degrade frequency regulation, increase converter current stress, and impose high-frequency current fluctuations on the battery. To address these issues, this paper proposes a multi-timescale transient-state sensing and signal-processing framework for grid-forming PV-hybrid storage systems. The proposed framework combines three coordinated functions. First, a frequency-domain HESS power-decoupling mechanism separates high-frequency transient power components and assigns them to the supercapacitor, while the battery mainly handles low-frequency energy variations. Second, a voltage-deviation-driven adaptive virtual inductance is introduced to increase the equivalent output impedance during voltage-sag events and reduce transient inrush current. Third, a noise-resilient frequency sensing strategy based on a filtered frequency derivative and a dead-band for false-trigger suppression is developed to reduce noise-induced false triggering in adaptive inertia and damping control. Comparative simulations indicate that under the tested weak-grid conditions, the proposed method reduces the transient inrush-current peak by 53.2%, decreases the maximum dynamic frequency deviation by approximately 75%, and improves the active-power regulation speed by more than 50%. These results indicate that the proposed sensing-oriented framework can improve transient response while reducing converter and battery current stress in PV-storage systems connected to high-impedance grids.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.