ArticleSensors (Basel, Switzerland)2026
A Time-of-Flight Extraction Method Based on Time-Sequenced Pulses for Ultrasonic Flow Measurement Using an FPGA-Based Time-to-Digital Converter.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The accuracy of transit-time ultrasonic flow measurement depends strongly on stable time-of-flight (TOF) extraction. However, threshold-based TOF methods are susceptible to emission transients, structural ringing, and repeated threshold crossings, which may cause false triggering and timing fluctuations. This paper proposes a time-of-flight extraction method based on time-sequenced pulses for ultrasonic flow measurement using an FPGA-based time-to-digital converter (TDC). The method equalizes signal input paths, combines peripheral path switching with FPGA gating to achieve windowed valid-edge extraction, and exploits the temporal correspondence among consecutive excitation pulses to construct multiple TOF observations from matched pulse pairs, thereby improving extraction stability and timing efficiency. A complete FPGA-TDC ultrasonic flow measurement platform based on a Zynq UltraScale+ device was developed, and TDC linearity, timing precision, and flow calibration experiments were conducted. After code-density calibration, the four channels achieved RMS values of about 20 ps, and within a flow range of 0.7-3.6 m
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.