Evidence map›Paper›PMID 42278027›Full record

ArticleAnimals : an open access journal from MDPI2026

Pilot Validation of a Novel Inline Device for Real-Time Monitoring of Abdominal Mechanics During Pneumoperitoneum.

Marta Guadalupi, Roberta Belvito, Floriana Cavalluzzo, Pietro Francesco Pio Magli, Agata Fraccascia, Francesco Staffieri, Luca Lacitignola

Abstract read
In one paragraph

Article in Animals : an open access journal from MDPI, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Marta GuadalupiDipartimento DiMePRe-J, Sez. Cliniche Veterinarie e p.a., Campus di Medicina Veterinaria, Università Degli Studi di Bari "Aldo Moro", s.p. per Casamassima km 3, Valenzano, 70010 Bari, Italy.ORCID 0009-0000-4917-355X
Roberta BelvitoDipartimento DiMePRe-J, Sez. Cliniche Veterinarie e p.a., Campus di Medicina Veterinaria, Università Degli Studi di Bari "Aldo Moro", s.p. per Casamassima km 3, Valenzano, 70010 Bari, Italy.ORCID 0009-0003-6395-3773
Floriana CavalluzzoDipartimento DiMePRe-J, Sez. Cliniche Veterinarie e p.a., Campus di Medicina Veterinaria, Università Degli Studi di Bari "Aldo Moro", s.p. per Casamassima km 3, Valenzano, 70010 Bari, Italy.
Pietro Francesco Pio MagliPhD Course SCICOV, Campus di Medicina Veterinaria, University of Bari, 70010 Bari, Italy.
Agata FraccasciaDipartimento DiMePRe-J, Sez. Cliniche Veterinarie e p.a., Campus di Medicina Veterinaria, Università Degli Studi di Bari "Aldo Moro", s.p. per Casamassima km 3, Valenzano, 70010 Bari, Italy.
Francesco StaffieriDipartimento DiMePRe-J, Sez. Cliniche Veterinarie e p.a., Campus di Medicina Veterinaria, Università Degli Studi di Bari "Aldo Moro", s.p. per Casamassima km 3, Valenzano, 70010 Bari, Italy.ORCID 0000-0002-2085-376X
Luca LacitignolaDipartimento DiMePRe-J, Sez. Cliniche Veterinarie e p.a., Campus di Medicina Veterinaria, Università Degli Studi di Bari "Aldo Moro", s.p. per Casamassima km 3, Valenzano, 70010 Bari, Italy.ORCID 0000-0003-4963-8673

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The abdominal pressure-volume (P-V) relationship during laparoscopic insufflation is curvilinear and subject to substantial inter-individual variability, yet clinical practice relies on universal pressure targets derived from population-level guidelines. The Smart Inline Compliance Module (SICM) is a novel inline retrofit device that acquires intra-abdominal pressure and insufflation gas flow through physically separated sensing circuits, reconstructs insufflated volume by numerical integration of the flow signal, and derives the abdominal P-V curve and its biomechanical parameters in real time. This study reports the first two-arm pilot technical evaluation of the SICM system. Arm A comprised an exploratory biomechanical phantom with three defined stiffness levels (Soft, Medium, Rigid) tested under Continuous and Stepwise insufflation protocols (30 curves). Arm B comprised three female feline cadavers assessed under the same dual-protocol design (18 curves). This study should be interpreted as an early-stage technical evaluation rather than as a definitive validation benchmark. Signal quality was consistently high across both arms (Curve Quality Index: 1.0000 in the phantom arm; 0.9974 ± 0.0009 in the cadaveric arm). Volume integration accuracy was confirmed against an independent offline reference (mean absolute percentage difference: 0.07%). The system extracted reproducible biomechanical parameters under the Continuous protocol: in the cadaveric arm, maximum compliance (Cmax) ranged from 116.8 to 191.4 mL/mmHg across subjects, with intra-session coefficients of variation below 16%; Knee Pressure (Pknee), defined as a working operational index of the compliance transition, was 3.33-4.17 mmHg with CV below 8%. The Rigid phantom and cadaveric datasets showed partial numerical overlap in selected shape-derived parameters, which was interpreted only as an internal consistency check and not as evidence of biomechanical equivalence. The Stepwise protocol exposed the current methodological limits of the parameter-extraction workflow and identified specific targets for the next development iteration. These results are interpreted exclusively within the scope of technical feasibility and preliminary biomechanical characterisation; clinical applicability and optimal pressure guidance require adequately powered in vivo studies.

Indexed as

abdominal compliancebiomechanical monitoringinline deviceinsufflationlaparoscopypneumoperitoneumpressure–volume curveveterinary surgery

Identifiers

PMID42278027
PMCPMC13255752

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.