Trends in cardiac implantable electronic device infections: 2015 to 2019.
Article in BMC cardiovascular disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Diagnostic and Management Challenges in a Non-Infectious Pacemaker Pocket Swelling: A Case Report and Literature Review.Diagnostics (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCardiovascular implantable electronic devices (CIEDs) improve survival in patients with cardiac rhythm disorders but carry risks of complications, most notably major infections. Reported infection rates vary internationally, and contemporary large-scale data from Germany are scarce. We aimed to determine nationwide rates of CIED infection-related hospitalizations and associated mortality over a five-year period.
methodsWe analyzed administrative claims from Germany's largest statutory health insurer covering more than 27 million beneficiaries. All CIED procedures performed between January 2015 and December 2019 were identified, including initial implantations, upgrades or downgrades, generator replacements, early revisions, and device extractions. Major infections were detected using International Classification of Diseases (ICD-10-GM) and procedural codes, and stratified as generator pocket infections or lead-associated endocarditis. In-hospital mortality was determined from discharge records.
resultsAmong 282,205 patients (57.7% male) undergoing CIED procedures, 6,577 individuals (2.33%) experienced 7,704 major infections within three months. Generator pocket infections occurred in 5,396 cases (1.91%), lead-associated endocarditis in 2,308 (0.82%), and combined infections in 1,127 patients (0.39%) within the acute 90-day observation period. CIED infections substantially increased healthcare utilization: Infected patients required substantially more procedures than non-infected patients, despite correct treatment. In-hospital mortality reached 8.36% for pocket infections and 15.0% for endocarditis. Extended follow-up in the 2015 cohort revealed a 4.33% infection-related procedure rate over five years.
conclusionsNationwide German data reveal higher acute CIED infection rates than previously reported, with considerable mortality and procedural burden. These findings highlight an urgent need for improved prevention and management strategies.