Evidence map›Paper›PMID 42277096›Full record

Trial reportScientific reports2026

Quantitative assessment of thoracolumbosacral orthosis efficacy on the temporal features of gait using inertial measurement unit sensors.

Zahra Gull, Asim Waris, Xing Chen, Muhammad Anees Ijaz, Muhammad Jawad Khan, Muhammad Adeel Ijaz, Falah Alanazi, Khalid Ansari, Syed Omer Gilani

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Zahra GullDepartment of Biomedical Engineering & Sciences, School of Mechanical and Manufacturing Engineering, National University of Science and Technology, Islamabad, Pakistan.
Asim WarisDepartment of Biomedical Engineering & Sciences, School of Mechanical and Manufacturing Engineering, National University of Science and Technology, Islamabad, Pakistan. asim.waris@smme.nust.edu.pk.
Xing ChenDepartment of Biomedical Engineering, School of Engineering Medicine, Beihang University, Beijing, China. xingc@buaa.edu.cn.
Muhammad Anees IjazDepartment of Mechanical Engineering, School of Mechanical Engineering and Automation, Beihang University, Beijing, China.
Muhammad Jawad KhanDepartment of Biomedical Engineering & Sciences, School of Mechanical and Manufacturing Engineering, National University of Science and Technology, Islamabad, Pakistan.
Muhammad Adeel IjazDepartment of Biomedical Engineering & Sciences, School of Mechanical and Manufacturing Engineering, National University of Science and Technology, Islamabad, Pakistan.
Falah AlanaziCollege of Engineering, Prince Sattam Bin Abdulaziz University, Al-Kharj, Saudi Arabia.
Khalid AnsariDepartment of Respiratory Care, Liwa University, Abu Dhabi, UAE.
Syed Omer GilaniDepartment of Electrical, Computer and Biomedical Engineering, Abu Dhabi University, Abu Dhabi, UAE.

Funding

Institutional Research Grant, Liwa University, Abu Dhabi IRG: MHS_001-2025
6 · The paper itself

Abstract

Prolonged sitting with poor spinal posture alter the biomechanics of spine and the whole body, alleviating gait efficiency and causing fatigue. Evidence suggest that spinal braces can correct postural deviations, enhance proprioception, postural control, and spinal stability. However, the impact of an abnormal posture and spinal brace on the temporal features of gait remains unexplored. This study aimed to assess the quantitative effectiveness of spinal brace on the temporal features of gait using IMU sensors. This randomized crossover experimental study involved 15 lab workers who performed gait trials under two walking conditions: with an abnormal posture, with spinal brace. Temporal gait parameters were analyzed at baseline and post intervention using 10-Meters Walk Tests using foot worn IMU sensors. A paired t-test (p < 0.05) was utilized to compare walking conditions, and Cohen's d quantified the spinal brace's effect on gait parameters. Wearing the brace resulted in improved gait symmetry index (p < 0.001, d= -2.54), stride time (p = 0.02, d= -0.29), stance time (p = 0.012, d= -0.57) and cadence (p = 0.048, d = 0.30), with spinal stability and walking efficiency reported by our participants. These findings suggest that the spinal brace is effective in improving gait efficiency in people with postural deviations.

Indexed as

BracesGaitOrthotic DevicesAdultBiomechanical PhenomenaCross-Over StudiesFemaleHumansMalePostureWalkingYoung AdultBiomechanicsGait analysisGait feature extractionIMU sensorsSpinal braceSpinal posture

Identifiers

PMID42277096
PMCPMC13554271

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.