ArticleScientific reports2026
Enhanced load frequency control using a novel fractional-order integral-integral-derivative controller optimized by cuckoo catfish optimizer.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Maintaining frequency stability in interconnected power systems (IPSs) is a critical challenge, particularly under sudden load changes and nonlinear constraints. Conventional PID and fractional-order controllers (FOPID, TID, FOID, and cascaded FO-PID structures) either lack adaptability or introduce excessive complexity. To overcome these limitations, this study introduces a novel fractional-order integral-integral-derivative (FOIID) controller that replaces the proportional term with a second-order fractional integrator. This dual-integral design yields 27 possible configurations, enhances the low-frequency gain, and eliminates the steady-state ramp error, thereby improving the transient and steady-state performance. The recently developed cuckoo catfish optimizer (CCO) is employed for parameter tuning. Unlike conventional metaheuristics (PSO, GA, and GWO), CCO integrates cooperative space compression, chaotic predation, and adaptive regeneration strategies, which avoid premature convergence and achieve a robust global search. The proposed CCO-FOIID framework was validated on a two-area non-reheat benchmark system and further tested on a three-area thermal-thermal-hydro system with generation rate constraints under 1% and 2% step load disturbances. A comparative analysis against five state-of-the-art controllers (ISFS-PID, DSA-FOPID, WHO-PI(1 + FOPID), and CGO-FOPID-FOPI) demonstrates that CCO-FOIID consistently achieves faster settling times, reduced overshoot, and the lowest ITAE value (74.26), outperforming the best competitor (CGO-FOPID-FOPI, 82.67). These results confirm that the combination of FOIID's universal structure and CCO's robust optimization provides a simple yet powerful solution for modern LFC applications in both simple and complex IPS networks.