Evidence map›Paper›PMID 42276837›Full record

ArticleJournal of applied clinical medical physics2026

Establishment and validation of a FLUKA radiation model for a medical electron linear accelerator room based on a virtual source.

Zhixin Wang, Liuqing Jiang, Huashan Sheng, Qichao Zhou, Senxing Zheng, Xiaobo Li

Abstract readValidation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zhixin WangSchool of Medical Imaging, Fujian Medical University, Fuzhou, China.
Liuqing JiangDepartment of Radiation Oncology, Fujian Medical University Union Hospital, Fuzhou, China.
Huashan ShengManteia Data Technology Co., Ltd, Xiamen, China.
Qichao ZhouManteia Data Technology Co., Ltd, Xiamen, China.
Senxing ZhengFujian Center for Prevention and Control of Occupational Diseases and Chemical Poisoning, Fuzhou, China.
Xiaobo LiSchool of Medical Imaging, Fujian Medical University, Fuzhou, China.

Funding

Fujian Provincial Department of Science and Technology 2023Y4019National Natural Science Foundation of China 1247050019
6 · The paper itself

Abstract

purposeIn Monte Carlo (MC) simulations of medical electron linear accelerator (linac) rooms using FLUKA, time-consuming modeling and simulation of the accelerator head are typically required, and FLUKA cannot directly read the phase space files (PSF) for accelerator heads provided by the IAEA. To address this, this study aimed to establish and validate the accuracy of a radiation model for an accelerator room within FLUKA using a virtual source, thereby enhancing the applicability of FLUKA for the design and evaluation of rooms housing different medical electron linacs.

methodsThe 6 MV photon beam from a Varian 23EX linac was modeled as consisting of primary photons, scattered photons, and contaminant electrons. Their energy spectra and spatial distributions were represented by mathematical formulas. Python code was used to sample particle information (type, position, direction, energy, weight) from this mathematically defined virtual source, generating a FLUKA-readable PSF. A room radiation model was then established in FLUKA. Its accuracy was validated by comparing simulated and measured percentage depth dose (PDD) and off-axis ratios (OAR) in a water tank, as well as comparing simulated and measured dose equivalent rates at selected points inside the accelerator room.

resultsThe deviation between simulated and measured PDD was within 1%, and that for the OAR was within 2%. At gantry angles of 0° and 90° (with the head oriented toward the maze inner entrance), the simulated dose-equivalent rates at the points of interest inside the treatment room closely agreed with the measured values.

conclusionThe phase-space file sampled from the virtual source can faithfully reproduce the beam characteristics in FLUKA. The agreement between simulation and measurement at the points of interest demonstrates that the room radiation model established in FLUKA using the virtual source accurately reflects the actual radiation field in the treatment room. This approach replaces the need for simulating the accelerator head model and improves the efficiency of using FLUKA for radiation protection studies on rooms equipped with different medical electron linear accelerators.

Indexed as

Computer SimulationElectronsModels, TheoreticalMonte Carlo MethodParticle AcceleratorsPhantoms, ImagingPhotonsRadiotherapy Planning, Computer-AssistedHumansRadiotherapy DosageScattering, RadiationFLUKAmedical electron linear acceleratorMonte Carloroom radiation modelvirtual source

Identifiers

PMID42276837
PMCPMC13259634

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.