Clinical Evidence and FDA Recalls of Artificial Intelligence-Enabled Medical Devices.
Article in JAMA network open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- From model failure to system harm: operationalizing a sociotechnical pathway for healthcare AI safety.Frontiers in artificial intelligence · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Artificial Intelligence (AI)-enabled medical devices present new safety challenges related to algorithmic complexity and evolving performance. Identifying device characteristics that influence recalls would be essential to caution against premature, widespread clinical deployment and to suggest increased surveillance. Objective: To test the hypothesis that AI-enabled medical devices lacking sufficient clinical evidence at approval have a higher hazard of recall. Design, Setting, and Participants: This retrospective cohort study included AI-enabled medical devices authorized by the US Food and Drug Administration (FDA) between August 11, 1995, and August 31, 2024. Devices were assessed from FDA authorization to recall or administrative censoring up to August 31, 2024. Adverse event reports were obtained from the FDA Manufacturer and User Facility Device Experience database and by using the Coordinating Research and Evidence for Medical Devices Postmarket Surveillance (CORE-MD PMS) Tool. Reports were mapped to International Medical Device Regulators Forum (IMDRF) codes to summarize device-related issues. Exposure: Device characteristics and occurrence of device problems. Main Outcomes and Measures: The primary outcome was time from FDA authorization to recall. Time to recall was analyzed using a bayesian Weibull survival model with regularized horseshoe priors. Associations were quantified using hazard ratios (HRs) and 95% credible intervals (CrIs) derived from the bayesian model. Results: Among 903 AI-enabled medical devices, 43 (4.8%) were recalled after a median (IQR) interval of 458 (263-1092) days. Devices with missing information regarding clinical studies had a higher hazard of recall than devices with published clinical studies (HR, 1.39; 95% CrI, 0.84-3.52). Devices flagged in the CORE-MD PMS Tool (HR, 4.28; 95% CrI, 1.01-13.10) or in both databases (HR, 2.77; 95% CrI, 0.87-14.28) had higher recall hazards. IMDRF codes showed that problems related to temperature (occurred for 1 of 9 recalls; HR, 0.45; 95% CrI, 0.03-1.26) and labeling (occurred for 2 of 9 recalls; HR, 0.55; 95% CrI, 0.06-1.37) were associated with lower hazards of recall. Incorrect use of the AI-enabled device (12 of 31 devices) was also associated with a higher estimated hazard of recall (HR, 3.33; 95% CrI, 0.97-10.71). Conclusions and Relevance: In this study of 903 FDA-authorized AI-enabled medical devices, missing information on supporting clinical studies was associated with a higher chance of recall; devices with use-related problems also were associated with elevated recall hazards. These findings highlight the importance of robust clinical validation and strengthened postmarket oversight for AI-enabled devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.