ArticleJournal of clinical monitoring and computing2026
A wearable cuffless blood pressure monitoring system: real-time measurement using force sensing and waveform analysis.
Article in Journal of clinical monitoring and computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper introduces a wearable, cuffless blood pressure (BP) monitoring system for continuous, real-time measurement in the operating room. Traditional cuff-based BP monitoring is intermittent and unsuitable for surgery, while intra-arterial measurements are invasive. The system uses a finger clip with a force sensor to detect pressure changes caused by arterial pulsations, with a waveform decomposition analysis algorithm estimating systolic and diastolic BP in real time. A clinical validation study involving 46 patients in the operating room demonstrated the system's accuracy, with reference measurements from an intra-arterial catheter. The reference systolic pressure ranged from 83 mmHg to 194 mmHg, and diastolic pressure from 42 mmHg to 105 mmHg. The error between paired measurements was - 1.44 ± 6.64 mmHg for systolic and 3.35 ± 6.91 mmHg for diastolic, with the device's measurements meeting the ISO 81060-2:2018 accuracy specification of 5 ± 8 mmHg. Pearson correlation coefficients were r = 0.90 (p < 0.01) for systolic and r = 0.78 (p < 0.01) for diastolic, indicating significant correlations with intra-arterial catheter measurements. The data analysis also considered the IEEE 1708 standard, ensuring compliance with guidelines for non-invasive BP monitoring. In collaboration with the device developer, the authors designed the clinical calibration protocol and user interface to ensure compatibility with intra-operative monitoring workflows. This study represents the first clinical validation of a tactile force-sensing cuffless system against intra-arterial reference measurements, demonstrating its feasibility for real-time, non-invasive blood pressure monitoring during anesthesia.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.