Evidence map›Paper›PMID 42273492›Full record

ArticleJournal of orthopaedic case reports2026

Short-term Clinical and Radiologic Outcomes, and Survivorship Following Primary Total Knee Arthroplasty Using a Novel High-Flexion System among Indian Patients.

Umesh Nagare, Venugopal Mahadevaiah Shringari, Mohandhas Ramasamy, Krishna Subramanyam

Abstract read
In one paragraph

Article in Journal of orthopaedic case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Umesh NagareDepartment of Orthopaedics, Vishwaraj Hospital, Pune, Maharashtra, India.
Venugopal Mahadevaiah ShringariDepartment of Orthopaedics, BIRRD Hospital, Tirupati, Andhra Pradesh, India.
Mohandhas RamasamyDepartment of Orthopaedics, Sushrushah Hospitals, Nagercoil, Tamil Nadu, India.
Krishna SubramanyamDepartment of Orthopaedics, Yashoda Hospitals, Hyderabad, Telangana, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: High-flexion total knee arthroplasty (TKA) prostheses permit deep knee flexion, which is important for day-to-day activities, especially among Indian patients. However, some high-flexion designs have been reported to be associated with early aseptic loosening and valgus instability in the past. Close monitoring of patients undergoing TKA using newer high-flexion prosthetic designs is imperative. The purpose of this study was to evaluate the short-term clinical outcomes and prosthetic survivorship of Indian patients following TKA using the Zenith® high-flexion system. Materials and Methods: Overall, 101 patients who underwent TKA using the Zenith® high-flexion system for osteoarthritis of the knee between June 2022 and August 2023 across four tertiary care hospitals were studied. Their pre-operative and post-operative knee range of movement and clinical evaluation scores were assessed. In addition, short-term prosthetic survivorship was assessed. Adverse events, if any, were recorded. Results: The study cohort included 51 men and 50 women with a mean age of 62.37 ± 6.96 years. Cruciate-retaining and posterior-stabilized prostheses were used in 58 and 43 patients, respectively. All patients were followed up for a minimum of 2 years postoperatively. Post-traumatic valgus instability necessitating revision TKA occurred in one patient; data pertaining to this patient were used for survivorship analysis, but not for evaluation of clinical outcome scores. Mild anterior notching occurred in one patient. No other adverse events were recorded. Knee flexion improved significantly from 97.82° ± 12.11° preoperatively to 114.11° ± 7.26° postoperatively (P < 0.001). Significant improvements in the Knee Society Knee Score (40.81 ± 15.18 preoperatively, to 88.58 ± 8.41 postoperatively) (P < 0.001) and Knee Society Functional Score (59.56 ± 16.43 preoperatively, to 95.69 ± 6.60 postoperatively) (P < 0.001) were noted. The mean Forgotten Joint Score at 2 years' follow-up was 87.64 ± 15.57. When revision for all causes was considered, the 2-year prosthetic survivorship as evaluated using a Kaplan-Meier plot was 99%. Conclusion: The Zenith® high-flexion system is associated with satisfactory short-term clinical outcomes and prosthetic survivorship. Further research is required to evaluate its performance in the mid- and long-term.

Indexed as

high flexionIndian patientsknee flexionknee replacementTotal knee arthroplastyZenith

Identifiers

PMID42273492
PMCPMC13248173

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.