Evidence map›Paper›PMID 42271182›Full record

ArticleScience progress

Comparison of an AI-based hand range of motion measurement with manual goniometry: A prospective cross-sectional pilot study in patients and healthy volunteers.

Fanbin Gu, Jingyuan Fan, Lulu Lv, Jiantao Yang, Qingtang Zhu, Honggang Wang

Abstract readComparative Study
In one paragraph

Article in Science progress. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fanbin GuDepartment of Microsurgery, Orthopedics Trauma and Hand Surgery, Sun Yat-sen University, The First Affiliated Hospital, Guangzhou, China.ORCID 0009-0001-8961-8389
Jingyuan FanDepartment of Microsurgery, Orthopedics Trauma and Hand Surgery, Sun Yat-sen University, The First Affiliated Hospital, Guangzhou, China.
Lulu LvDepartment of Microsurgery, Orthopedics Trauma and Hand Surgery, Sun Yat-sen University, The First Affiliated Hospital, Guangzhou, China.
Jiantao YangDepartment of Microsurgery, Orthopedics Trauma and Hand Surgery, Sun Yat-sen University, The First Affiliated Hospital, Guangzhou, China.
Qingtang ZhuDepartment of Microsurgery, Orthopedics Trauma and Hand Surgery, Sun Yat-sen University, The First Affiliated Hospital, Guangzhou, China.
Honggang WangDepartment of Microsurgery, Orthopedics Trauma and Hand Surgery, Sun Yat-sen University, The First Affiliated Hospital, Guangzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

ObjectiveManual goniometry is the standard for hand range of motion assessment but is time-consuming and requires in-person visits. This pilot study aimed to develop an AI-based measurement method and to compare its agreement with manual goniometry in both healthy volunteers and patients.MethodsIn this prospective cross-sectional pilot study (July 2022 to February 2023), an AI-based method was developed using six hand gestures and MediaPipe Hands. Geometric optimization was used for metacarpophalangeal and proximal interphalangeal flexion measurements. For comparison, manual goniometry was performed to evaluate measurement errors. Agreement was evaluated using the intraclass correlation coefficient (ICC) and Bland-Altman analysis.ResultsThe study consisted of 25 healthy individuals (50 hands) and 34 patients (68 hands). The mean difference between the AI-based method and manual measurements was 0.4°±8.8°. Geometric optimization reduced the mean absolute error by 13.5° for metacarpophalangeal and proximal interphalangeal flexion measurements and by 3.5 percentage points for Swanson score. Across all parameters, the overall mean absolute error was 5.14°, root mean square error was 7.05°, and normalized RMSE was 8.7%. For the Swanson score, the method demonstrated excellent consistency (ICC: 0.95) with the manual measurements, and Bland-Altman analysis showed a narrower 95% limits of agreement after optimization (-3.5%, 7.7%) compared to the pre-optimized results (-2.4%, 13.2%).ConclusionsThis AI-based method showed acceptable agreement with manual goniometry for most measurements. The Swanson score measurement was clinically acceptable, but thumb movements and proximal interphalangeal flexion require further refinement. The method may serve as a supportive tool for hand function assessment, pending validation in more severe hand impairments and varied environmental conditions.

Indexed as

Arthrometry, ArticularHandRange of Motion, ArticularAdultCross-Sectional StudiesFemaleHealthy VolunteersHumansMaleMiddle AgedPilot ProjectsProspective StudiesYoung Adultautomatic measurementfunction evaluationhand functionpose estimationrange of motion

Identifiers

PMID42271182
PMCPMC13254418

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.