Evidence map›Paper›PMID 42268300›Full record

ArticleEuropean radiology2026

Comparative evaluation of generative AI models for chest radiograph report generation in the emergency department.

Woo Hyeon Lim, Ji Young Lee, Jong Hyuk Lee, Saehoon Kim, Hyungjin Kim

Abstract readComparative Study
In one paragraph

Article in European radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Woo Hyeon Lim *Department of Radiology, Seoul National University Hospital, Jongno-gu, Korea.
Ji Young Lee *Department of Radiology, Seoul National University Hospital, Jongno-gu, Korea.
Jong Hyuk LeeDepartment of Radiology, Seoul National University Hospital, Jongno-gu, Korea.
Saehoon KimSoombit.ai, Bundang-gu, Korea.
Hyungjin KimDepartment of Radiology, Seoul National University Hospital, Jongno-gu, Korea. kiche29@snu.ac.kr.ORCID http://orcid.org/0000-0003-0722-0033

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo benchmark medical image-specific vision-language models (VLMs) against real-world radiologist-written reports, focusing on diagnostic quality, clinical acceptability, hallucinations, and language clarity. MATERIALS AND

methodsThis retrospective study included adult patients who presented to the emergency department of a tertiary center between January 2022 and April 2025 and underwent same-day chest radiograph (CXR) and CT for febrile or respiratory symptoms. Reports from five VLMs (AIRead, Lingshu, MAIRA-2, MedGemma, and MedVersa) and radiologist-written reports were randomly presented and blindly evaluated by three thoracic radiologists using four criteria: RADPEER, clinical acceptability, hallucination, and language clarity. Comparative performance was assessed using generalized linear mixed models, with radiologist-written reports treated as the reference. Finding-level analyses were also performed with CT as a reference.

resultsA total of 478 patients (median age, 67 years [interquartile range, 50-78]; 282 males [59.0%]) were included. AIRead demonstrated the lowest RADPEER 3b rate (5.3% [76/1434] vs radiologists 13.9% [200/1434]; p < 0.001) and the highest clinical acceptability (84.5% [1212/1434] vs radiologists 74.3% [1065/1434]; p < 0.001), with hallucination rates comparable to radiologists (0.3% [4/1425]) vs 0.1% [1/1425]; p = 0.21). Other VLMs showed higher disagreement (16.8-43.0%; p < 0.05), lower acceptability (41.1-71.4%; p < 0.05), and more frequent hallucinations (5.4-17.4%; p < 0.05). Language clarity was higher for several VLMs (AIRead, Lingshu, and MedVersa) than for radiologist-written reports (82.9-88.4% [1189-1268/1434] vs 78.1% [1120/1434]; p < 0.05). Finding-level analyses showed substantial variability in sensitivity across VLMs for common thoracic findings.

conclusionMedical VLMs for CXR report generation exhibited variable performance in report quality and diagnostic measures. KEY POINTS: Question How do medical VLMs perform compared with radiologist-written reports regarding diagnostic quality, clinical acceptability, hallucinations, and language clarity for CXRs? Findings One non-open-source VLM achieved the lowest RADPEER 3b rate and highest acceptability with radiologist-level hallucinations, whereas other models showed inferior performance. Clinical relevance VLMs may support automated preliminary CXR reporting and serve as adjunct tools to enhance workflow efficiency and consistency. Although performance varied widely, carefully developed models approached radiologist-level quality, supporting continued refinement and targeted clinical integration.

Indexed as

Emergency Service, HospitalRadiography, ThoracicAgedFemaleGenerative Artificial IntelligenceHumansMaleMiddle AgedRadiologistsRetrospective StudiesTomography, X-Ray ComputedDiagnostic imagingGenerative artificial intelligenceNatural language processingRadiography (Thoracic)Radiologists

Identifiers

PMID42268300
PMCPMC13574732

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked