Evidence map›Paper›PMID 42266229›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2026

Impact of DOI Capability on Detector Performance: A Comparative Study of DOI and Non-DOI Detectors for High-Resolution and Sensitivity Organ-Specific PET Inserts.

Lukas U Rauscher, Magdelena S Allen, Martin S Judenhofer, Larry Byars, Michele Scipioni, José M Udias, Ciprian Catana, Bernd J Pichler, Fabian P Schmidt

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lukas U RauscherWerner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, 72076 Tuebingen, Germany.
Magdelena S AllenDepartment of Physics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA and Athinoula A. Martinos Center for Biomedical Imaging, Radiology Department, Massachusetts General Hospital, Boston, MA 02129, USA.
Martin S JudenhoferMolecular Imaging, Siemens Medical Solutions USA Inc., Knoxville, USA.
Larry ByarsMolecular Imaging, Siemens Medical Solutions USA Inc., Knoxville, USA.
Michele ScipioniAthinoula A. Martinos Center for Biomedical Imaging, Radiology Department, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02129, USA.
José M UdiasNuclear Physics Group and IPARCOS, Universidad Complutense de Madrid, Madrid, Spain.
Ciprian CatanaAthinoula A. Martinos Center for Biomedical Imaging, Radiology Department, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02129, USA.
Bernd J PichlerWerner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, 72076 Tuebingen, Germany and also with Cluster of Excellence iFIT (EXC 2180) "Image Guided and Functionally Instructed Tumor Therapies", University of Tuebingen, Tübingen, Germany.
Fabian P SchmidtWerner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, 72076 Tuebingen, Germany and also with Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, 72076 Tübingen, Germany.

Funding

Development of the Human Dynamic Neurochemical Connectome ScannerU01EB029826 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI CATANA, CIPRIAN · 2020 to 2025
$7.1M
NIBIB NIH HHS U01 EB029826
6 · The paper itself

Abstract

High-sensitivity organ-specific PET inserts employing long scintillation crystals in combination with small ring diameters require depth-of-interaction (DOI) encoding to ensure uniform spatial resolution across the field of view. In this study, we have developed high-resolution, DOI-capable detectors based on the Hamamatsu C13500 TOF-PET modules, using 1.6×1.6 mm

Indexed as

Brain PETBreast PETDepth of InteractionDOIPET DetectorPET/MRI

Identifiers

PMID42266229
PMCPMC13246148

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.