ArticleRadiological physics and technology2026
Comparison of fat-suppression-related sequence operations for stiffness stability in spin-echo echo-planar imaging magnetic resonance elastography: a phantom study.
Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Spin-echo echo-planar imaging (SE-EPI)-based magnetic resonance elastography (MRE) is susceptible to chemical shift artifacts, making sequence-related operations important for stable measurements. This phantom study evaluated the influence of fat-suppression-related sequence operations on stiffness measurement variability in SE-EPI MRE. Imaging was performed at 3-T under six conditions, with five repeated acquisitions and four slices per scan. Mean stiffness, variability, and measurable area were assessed using the average coefficient of variation (aCV), and signal-to-noise ratio (SNR) was quantitatively evaluated. All conditions yielded stiffness values within the expected range. Spectral attenuated inversion recovery with strong showed the lowest aCV (0.7%), whereas water excitation showed the highest aCV (6.0%) and the smallest measurable area. Sequence-related differences were associated with variability, suggesting contributions from SNR and sequence-dependent signal characteristics affecting stiffness stability.