IOL Calculators Variability in Toric Lens Planning: A Retrospective Paired Comparison of the Planning Discrepancies Between the Johnson & Johnson Toric Calculator and ESCRS-Hosted Engines.

Michal Klimek, Maximilian Tamberger, Stephanie Schauer, Dejan Botic, Kata Mihaltz, Pia Veronika Vécsei-Marlovits

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Michal KlimekDepartment of Ophthalmology, Klinik Hietzing, Wiener Gesundheitsverbund, Vienna, Austria.ORCID 0009-0006-0722-4543
Maximilian TambergerDepartment of Ophthalmology, Klinik Hietzing, Wiener Gesundheitsverbund, Vienna, Austria.ORCID 0009-0008-6901-1660
Stephanie SchauerDepartment of Ophthalmology, Klinik Hietzing, Wiener Gesundheitsverbund, Vienna, Austria.
Dejan BoticDepartment of Ophthalmology, Klinik Hietzing, Wiener Gesundheitsverbund, Vienna, Austria.ORCID 0009-0008-1134-6249
Kata MihaltzDepartment of Ophthalmology, Klinik Hietzing, Wiener Gesundheitsverbund, Vienna, Austria.
Pia Veronika Vécsei-MarlovitsDepartment of Ophthalmology, Klinik Hietzing, Wiener Gesundheitsverbund, Vienna, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To determine the frequency, magnitude, and direction of toric intraocular lens (IOL) planning discrepancies between the Johnson & Johnson (J&J) official calculator and European Society of Cataract and Refractive Surgeons (ESCRS)-hosted toric engines, and to identify preoperative predictors of clinically relevant disagreements. Methods: This retrospective, single-center study included 182 eyes of 127 patients undergoing toric IOL implantation (TECNIS). For each eye, planning results were generated using identical biometric data (IOLMaster 700, CASIA2 keratometry) across all calculators. The primary comparison was J&J with posterior corneal astigmatism correction enabled (PCA-ON) versus ESCRS-Barrett - secondary comparisons included Kane, EVO 2.0, and Hoffer QST. Clinically relevant discrepancy (ClinRel) was defined as a toric cylinder step difference ≥ 1 and/or axis difference ≥ 10°. Logistic regression, including Firth-penalized estimation, identified predictors of ClinRel. The primary analysis set comprised one eye per patient (n=127). Results: ClinRel between J&J PCA-ON and Barrett occurred in 59.8% of eyes (76/127; 95% CI: 51.1-68.0%), driven almost only by step differences. J&J PCA-ON recommended a higher step in 56.7% of eyes, with only 2.4% showing the opposite. Discrepancies were concentrated in with-the-rule eyes (72.3%) and nearly absent in against-the-rule eyes (5.6%). Rates were higher for secondary engines (Kane 83.8%, EVO 74.4%, Hoffer QST 76.7%). An Alpins-style paired-planning analysis yielded a Correction Index of 1.20, with the Difference Vector concentrated at the vertical meridian (84°). Posterior corneal astigmatism grade was the strongest independent predictor (Firth-adjusted OR = 203.5; p=0.014). An empirical PCA threshold of 0.36 D (Youden index; sensitivity 91.6%, specificity 56.0%) identified eyes at elevated risk of calculator disagreement. Conclusion: Calculators' variability in toric IOL planning is substantial (~60% of eyes) and concentrated in with-the-rule eyes with elevated posterior corneal astigmatism. In this subgroup, consulting multiple calculators is recommended; in against-the-rule eyes, calculator choice rarely alters the recommendation.

Indexed as

calculator comparisonESCRS toric calculatorJohnson & Johnson toric calculatorposterior corneal astigmatismtoric IOLtoric planning variability