ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2026
Modified spinopelvic fixation with a novel three-dimensional-printed element following total sacrectomy for patients with sacral tumours.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTotal sacrectomy is now a standard curative procedure for primary malignant sacral tumours. Reconstruction, however, remains demanding because of the complex regional anatomy and unique biomechanical environment. Several spinopelvic reconstruction techniques have been reported, all yielding satisfactory functional outcomes. This study aims to evaluate both the clinical outcomes and the biomechanical behavior of a modified spinopelvic fixation construct, which incorporates a novel three-dimensional-printed component following total sacrectomy.
methodsWe conducted a retrospective cohort study of 12 consecutive patients (4 men, 8 women; mean age 38 years, range 17-61 years) treated between 2021 and 2024. Eleven patients with primary malignant sacral tumours underwent total en-bloc sacrectomy, and one patient with a giant-cell tumour (GCT) underwent piecemeal resection. All patients received modified spinopelvic reconstruction. Tumour extent was L5-S5 in two patients with recurrent malignant peripheral nerve sheath tumour (MPNST), S1-S5 in eight patients with primary malignancies, S1-S5 in the patient with GCT, and S1-S5 with extension into pelvic zones I/IV in one patient with osteosarcoma. Operative time, oncological outcomes, functional outcomes, complications, and implant status were all reviewed. A finite-element analysis was performed to evaluate the biomechanical behaviour of the novel construct and to compare it with previously described reconstruction models.
resultsAll 12 patients had a confirmed histological diagnosis before surgery. Three osteosarcoma and four malignant peripheral nerve sheath tumour (MPNST) patients received neoadjuvant and postoperative chemotherapy; one giant-cell tumour (GCT) patient was treated with denosumab. Mean operative time was 11.5 h (range 7.5-15 h) and mean intra-operative blood loss was 2,616 ml (range 1,200-4,000 ml). During follow-up, local recurrence was detected in two chordoma cases. Functionally, S1-S5 root transection caused sphincter disturbance in 11 patients; two of these also sacrificed a unilateral L5 root, yet none required colostomy or chronic catheterisation. Nine patients lost dorsiflexion strength. At the latest follow-up, 10 patients could walk independently, and 2 required assistive devices. No major perioperative complications were observed; three patients experienced wound healing complications, which were successfully managed with simple debridement, suturing, and negative pressure wound therapy. Only one overweight patient experienced unilateral iliac screw failure without further revision; the remaining 11 patients had no mechanical complications. Finite-element analysis suggested that the current reconstruction may have favorable load-bearing capacity and stability characteristics compared with previously described models.
conclusionThe modified spinopelvic fixation with the fifth rod and 3D-printing element represents a potential option for anterior column reconstruction after total sacrectomy, with preliminary evidence of satisfactory clinical outcomes in non-overweight patients. Finite-element analysis suggests that the construct may possess adequate stiffness and stability characteristics that could contribute to preventing pelvic-spinal collapse, though these biomechanical findings require further clinical validation. Stress values from the finite-element model indicate a theoretically low risk of implant fracture under static loading or fatigue conditions, but long-term follow-up is necessary to confirm implant durability and exclude late complications such as loosening or breakage.
Indexed as
Identifiers
42260154What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.