Marked Respiratory Improvement After ECMO-Supported Exchange From Metallic to Silicone Stent in Tracheobronchial Stenosis due to Tuberculosis: A Case Report.

Mayu Goda, Yuki Takigawa, Ken Sato, Kenichiro Kudo, Satoko Ido, Mitsuki Furutaguchi, Yuka Matsuo, Keisuke Shiraha, Suzuka Matsuoka, Jun Nishimura and 7 more

Abstract read
In one paragraph

Article in Respirology case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors.

Mayu GodaDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.
Yuki TakigawaDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.ORCID https://orcid.org/0000-0003-0613-0423
Ken SatoDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.
Kenichiro KudoDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.
Satoko IdoDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.
Mitsuki FurutaguchiDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.
Yuka MatsuoDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.
Keisuke ShirahaDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.
Suzuka MatsuokaDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.
Jun NishimuraDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.
Hiromi WatanabeDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.
Shunsuke ChikamaDepartment of Cardiology NHO Okayama Medical Center Okayama City Japan.
Masataka ShigetoshiDepartment of Cardiology NHO Okayama Medical Center Okayama City Japan.
Yuko NishimuraDepartment of Anesthesiology Medicine NHO Okayama Medical Center Okayama City Japan.
Satoshi NogamiDepartment of Anesthesiology Medicine NHO Okayama Medical Center Okayama City Japan.
Hiromasa TakedaDepartment of Internal Medicine Tsuyama Central Hospital Tsuyama City Japan.
Keiichi FujiwaraDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama City Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A woman in her mid-50s with tracheobronchial stenosis due to tuberculosis underwent covered metallic stent insertion via flexible bronchoscopy at a referral hospital. Subsequently, an additional silicone Y stent was inserted via rigid bronchoscopy to relieve stenosis distal to the metallic stent. Although her respiratory condition improved markedly after stenting, long-term complications related to metallic stents such as stent fracture and restenosis were anticipated. Seven months after the first metallic stent insertion, both stents were removed and replaced with silicone stents in accordance with guidelines for the management of benign tracheobronchial stenosis, under veno-venous extracorporeal membrane oxygenation (ECMO) support without systemic anticoagulation. The procedure was completed successfully without intraoperative complications. Following the insertion of two silicone stents, her respiratory symptoms and pulmonary function improved as the silicone stents seemed to have provided her airway with more stable support. We report a case of successful metallic-to-silicone stent replacement under ECMO support in a patient with severe benign airway stenosis.

Indexed as

ECMOpulmonary interventionrigid bronchoscopytracheobronchial stenosis

Identifiers

PMID42256659
PMCPMC13239613

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.