ArticleACS omega2026
Development of Green HPLC-PDA Method for Quantification and Extraction Optimization of Dihydromyricetin, Vitexin, and Isovitexin in the LCD20 Herbal Remedy.
Article in ACS omega, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Dihydromyricetin, vitexin, and isovitexin are bioactive compounds in the LCD20 herbal remedy, valued for their role in peptic ulcer treatment. This study presents the development and validation of a green HPLC-PDA method for the simultaneous quantification of these three compounds in the remedy. Chromatographic separation was achieved using an InertSustain C18 column (4.6 × 250 mm, 5 μm) with a mobile phase of acetonitrile and 0.1% formic acid (13:87, v/v) and detection at 330 nm. The method demonstrated excellent linearity with ranges of 25-1000 μg/mL for dihydromyricetin and 5-200 μg/mL for vitexin and isovitexin. The method demonstrated high sensitivity with low limits of detection and quantification. The method also exhibited satisfactory specificity, accuracy, precision, sensitivity, and stability. Greenness assessment confirmed the method's alignment with green analytical chemistry, with AGREE (0.56), Eco-Scale (77), ComplexGAPI classification as low risk, and a BAGI score of 67.5. Finally, the validated method was utilized to optimize the manufacturing process of the herbal extract via response surface methodology; conditions of 84.3% ethanol, 11.4 mL/g solvent-to-solid ratio, and 4.86 h were established for maximum efficiency. This approach ensures reliable quantification and extraction, aiding the standardization of LCD20 for pharmaceutical use.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.