Shear-wave ultrasound elastography for tissue-specific quantification of radiation-induced cervical fibrosis.

Hendrik Dapper, Maria Waltenberger, Steffi U Pigorsch, Stephanie E Combs, Katharina Bauermeister, Wolfgang Bauermeister

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Hendrik DapperDepartment of Radio-Oncology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Maria WaltenbergerDepartment of Radio-Oncology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Steffi U PigorschDepartment of Radio-Oncology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Stephanie E CombsDepartment of Radio-Oncology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Katharina BauermeisterDepartment of Neurology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Wolfgang BauermeisterConservative and Rehabilitative Orthopaedics, TUM School of Medicine and Health, Technical University of Munich, Campus D, Am Olympiacampus 11, 80809 Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Radiation-induced cervical fibrosis is a common late effect following radiotherapy for head and neck cancer, potentially leading to reduced tissue compliance and functional impairment. Objective assessment, however, remains challenging in clinical practice. Therefore, this study aimed to evaluate the feasibility of shear-wave ultrasound elastography (SWE) for quantitative, tissue-specific assessment of radiation-induced cervical fibrosis. Materials and methods: Sixteen patients after bilateral cervical lymphatic irradiation were compared with sixteen age-, sex-, and body mass index-matched controls without prior head and neck irradiation. SWE was used to quantify stiffness of muscle, fascia, and subcutaneous tissue of the sternocleidomastoid muscle. Ultrasound-based thickness measurements and assessment of cervical range of motion were additionally performed. Results: Mean muscle stiffness was significantly higher in irradiated patients compared with controls (left: 46.98 vs. 28.10 kPa; right: 46.75 vs. 21.52 kPa). Comparable increases were observed in the fascia (left: 46.41 vs. 25.47 kPa; right: 44.28 vs. 22.69 kPa), whereas differences in subcutaneous tissue were less pronounced. Muscle and skin thickness were significantly reduced after radiotherapy. Cervical range of motion did not differ significantly between groups, although a non-significant reduction of approximately 5° in cervical rotation was observed. Negative correlations between muscle stiffness and cervical range of motion were observed but did not reach statistical significance. Conclusion: Shear-wave elastography enables reliable, tissue-specific quantification of radiation-induced cervical fibrosis, predominantly affecting muscle and fascia. Despite increased tissue stiffness and reduced thickness, cervical range of motion remained largely preserved, suggesting a dissociation between structural tissue alterations and functional impairment.

Indexed as

FibrosisHead and neck cancerRadiationShear-wave ultrasoundelastography

Identifiers

PMID42255162
PMCPMC13241838

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.