Evidence map›Paper›PMID 42255058›Full record

ArticleHealth science reports2026

Effects of Computer Assisted Design-Computer Assisted Manufacturing Nickel-Titanium Fixed Lingual Retainers Versus Conventional Flexible Multistrand Retainers on Tooth Displacements and Periodontal Ligament Stress Distributions in the Mandibular Anterior Teeth at Four Different Inclinations: A Finite Element Analysis.

Hanie Daryanavard, Marzieh Mazhari, Mohsen Mazhary, Hooman Ghazi Oskouei, Mehrnaz Moradinejad, Shole Shahi, Vahid Rakhshan

Abstract read
In one paragraph

Article in Health science reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hanie DaryanavardDepartment of Orthodontics, School of Dentistry Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran.
Marzieh MazhariDepartment of Orthodontics, School of Dentistry Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran.
Mohsen MazharyDepartment of Civil and Environmental Engineering ACECR Institute for Higher Education Ahvaz Iran.
Hooman Ghazi OskoueiDepartment of Orthodontics, School of Dentistry Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran.
Mehrnaz MoradinejadDepartment of Orthodontics, School of Dentistry Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran.
Shole ShahiDepartment of Orthodontics, School of Dentistry Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran.
Vahid RakhshanDepartment of Anatomy, School of Dentistry Azad University of Medical Sciences Tehran Iran.ORCID https://orcid.org/0000-0002-9503-3133

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aims: Little information is available on tooth displacement and periodontal ligament (PDL) stress distribution caused by computer assisted design-computer assisted manufacturing (CAD/CAM) retainers. Therefore, the purpose of this study was to compare CAD/CAM and multistrand retainers in terms of PDL stresses, risk of root resorption, and displacements of mandibular anterior teeth with 4 different inclinations using finite element analysis. Methods: In this computer-based finite element simulation, eight models consisting of the six mandibular anterior teeth, their PDLs, and surrounding alveolar bones were created. Four models simulated conventional fixed retainers with multistrand wires; four others simulated CAD/CAM nickel-titanium fixed retainers. Within each retainer group, four different tooth inclinations relative to the horizontal plane (inclination angles of 110°, 100°, 90°, and 80°) were modeled. All models were subjected to a vertical pressure of 42 psi (0.289 MPa, exerted on the incisal surfaces) and a lingual force of 10 N. Calculated were PDL stresses, the risk of root resorption (defined as areas where PDL stress exceeded 0.0047 MPa), and dental displacements along the buccolingual and intrusive/extrusive axes. Results: With fixed multi-strand retainers, the buccolingual displacements of incisor and canine crowns are 3.10, 6.10, and between 2.82 and 5.32 µm in the lingual side. As the inclination increases, displacement and strain are often increased. In the CAD/CAM models, the buccolingual displacements of the crown of incisors and canines were between 2.94 and 4.76 µm and 3.34 and 4.01 µm in the lingual side, respectively. By increasing the inclination, the displacement and strain often decreased. Conclusion: Although this FEA study showed some differences between models, no clinical recommendation is possible. Clinical decisions must also consider breakage modes, undetected debonding risk, and patient follow-up.

Indexed as

CAD‐CAM retainercomputer assisted design‐computer assisted manufacturingfixed retainersmultistrand wirenickel‐titaniumretentionroot resorption

Identifiers

PMID42255058
PMCPMC13240510

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.