Evidence map›Paper›PMID 42254812›Full record

ReviewRadiology advances2026

Clinical benefits and current challenges of photon-counting detector CT in vascular imaging.

Ahmed O El Sadaney, Felix E Diehn, Prabhakar Shantha Rajiah, Ian Mark, Norbert G Campeau, Adam T Froemming, Francis I Baffour, Kelly K Horst, Lifeng Yu, Shuai Leng and 2 more

Abstract readReview
In one paragraph

Review in Radiology advances, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Ahmed O El SadaneyDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.
Felix E DiehnDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.
Prabhakar Shantha RajiahDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.
Ian MarkDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.
Norbert G CampeauDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.ORCID https://orcid.org/0000-0002-0688-5781
Adam T FroemmingDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.ORCID https://orcid.org/0000-0001-7706-8060
Francis I BaffourDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.ORCID https://orcid.org/0000-0001-8005-4823
Kelly K HorstDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.
Lifeng YuDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.ORCID https://orcid.org/0000-0002-4267-1326
Shuai LengDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.ORCID https://orcid.org/0000-0002-6453-9481
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.ORCID https://orcid.org/0000-0002-5346-332X
Joel G FletcherDepartment of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.ORCID https://orcid.org/0000-0002-8941-5434

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Photon-counting detector CT (PCD-CT) directly detects individual photons and measures their energies, enabling the acquisition of multi-energy data from a single x-ray source with higher spatial resolution, thereby allowing visualization of smaller arteries and veins and other important imaging features not seen at conventional CT. It also substantially reduces calcium and stent blooming artifacts. Appropriate patient selection and task-based optimization of acquisition, reconstruction, and interpretation are critical to realize these benefits. Vascular imaging examinations for which early evidence shows that PCD-CT demonstrates higher diagnostic performance compared to conventional CT include coronary CT angiography (CTA) for evaluation of partially calcified plaques or stents, peripheral runoff CTA, detection of cerebrospinal fluid-venous fistulas, and head CTA for evaluation of small intracranial vessels and aneurysms. Current limitations include excessive image noise with the sharpest reconstruction kernels and challenges when adapting conventional CT protocols (eg, requiring sharper kernels, thinner slices, higher matrices, tailored scan modes) to achieve time-efficient image reconstruction and hanging protocols. New solutions and directions will include deep-learning-based image noise reduction, improved spectral separation, strategic triage of specific patient populations to PCD-CT systems, and subspecialty clinical practice recommendations for this new technology.

Indexed as

angiographyatherosclerosiscerebrospinal fluid-venous fistulacerebrovascular disorderscoronary artery diseaseperipheral vascular diseasesphoton-counting-detector CTrun-off CTA

Identifiers

PMID42254812
PMCPMC13234556

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.