ArticleAnnals of medicine and surgery (2012)2026
IoMT-enabled implant sensors for early detection of neurovascular complications in craniofacial distraction osteogenesis.
Article in Annals of medicine and surgery (2012), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Craniofacial distraction osteogenesis (DO) is an established surgical technique for correcting complex craniofacial deformities and managing upper airway obstruction. Neurovascular complications, including injury to the inferior alveolar, infraorbital, and facial nerves, are recognized risks of the procedure. Current postoperative surveillance depends on periodic clinical examination and interval imaging, neither of which provides continuous insight into the mechanical forces transmitted to adjacent neurovascular structures during the active distraction phase. This letter examines whether implantable sensor technologies integrated with Internet of Medical Things (IoMT) infrastructure could address this monitoring gap. Micro-sensors capable of monitoring strain, pressure, and temperature at the tissue-implant interface have been demonstrated in musculoskeletal applications and are technically transferable to craniofacial distraction hardware. Continuous strain monitoring could detect abnormal force accumulation along the distraction vector before neurovascular injury thresholds are reached. Closed-loop feedback architectures could further allow dynamic modulation of distraction parameters in response to real-time physiological signals, reducing reliance on fixed-schedule activations that do not account for individual tissue response. No clinical studies have yet evaluated IoMT sensor integration in craniofacial DO, and significant barriers remain, including sensor biocompatibility, device miniaturization for pediatric use, wireless signal transmission through bone, and data security. Prospective feasibility studies are required before this approach can be considered for clinical implementation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials