Evidence map›Paper›PMID 42250173›Full record

ArticleArchives of orthopaedic and trauma surgery2026

Biomechanical comparison of inverted triangle and L-shaped screw configurations with medial buttress and anteromedial support plate in Pauwels type III femoral neck fractures.

Murat Erem, Utku Demirtaş, Savaş Yıldırım, Eşref Selçuk, Cem Çopuroğlu

Abstract readComparative Study
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Murat EremDepartment of Orthopaedics and Traumatology, Trakya University, Edirne, Turkey. muraterem@trakya.edu.tr.
Utku DemirtaşDepartment of Orthopaedics and Traumatology, Sultan 1.Murat State Hospital, Edirne, Turkey. opdrutkudemirtas@gmail.com.
Savaş YıldırımDepartment of Orthopaedics and Traumatology, Trakya University, Edirne, Turkey.
Eşref SelçukDepartment of Orthopaedics and Traumatology, Trakya University, Edirne, Turkey.
Cem ÇopuroğluDepartment of Orthopaedics and Traumatology, Trakya University, Edirne, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionSurgical stabilization of Pauwels Type III femoral neck fractures remains a significant challenge due to high vertical shear forces. While the medial buttress plate is a recognized solution, it requires extensive deep dissection. This study aims to compare the biomechanical performance of various screw configurations combined with either a medial buttress or anteromedial support plate. MATERIALS AND

methodsTwenty-five third-generation synthetic femurs were used to create a standardized 70-degree (Pauwels III) fracture model. Specimens were divided into five groups (n = 5): (A) Inverted triangle (IT) screws with a Pauwels screw, (B) Inverted triangle (IT) with medial buttress plate (MBP), (C) Inverted triangle with anteromedial support plate (ASP), (D) L-configuration with medial buttress plate (MBP), and (E) L-configuration with anteromedial support plate (ASP). Axial loading was applied at 2 mm/min until construct failure, defined objectively by the real-time force-distance curve.

resultsAlthough no statistically significant difference was found between groups (p = 0.102), a large effect size was observed (η² = 0.309). Group C (IT + ASP) demonstrated the highest mean failure load (1695 ± 494.6 N). Conversely, Group E (L-configuration + ASP) exhibited the lowest stability (977.2 ± 195.4 N) with a remarkably narrow standard deviation. The majority of failures occurred as transverse subtrochanteric fractures distal to the implants.

conclusionThe combination of an inverted triangle screw arrangement with an anteromedial support plate demonstrated comparable biomechanical stability to the medial buttress plate, while offering a potentially safer surgical corridor. Conversely, pairing L-shaped screw configurations with anteromedial support plates resulted in the lowest mean ultimate load-to-failure among the tested constructs, likely due to potential stress riser effects.

Indexed as

Bone PlatesBone ScrewsFemoral Neck FracturesFracture Fixation, InternalBiomechanical PhenomenaHumansProximal Femoral FracturesAnteromedial support plateBiomechanical testingFemoral neck fractureInternal fixationMedial buttress platePauwels type III

Identifiers

PMID42250173
PMCPMC13242485

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.