ArticleBMC medical imaging2026

Deformable image registration accuracy: impact of user-defined parameter selection on contour propagation for deep inspiration breath-hold and free breathing breast radiotherapy.

Stefan Knippen, Lea Pargmann, Steffen Weimann, Guido Hildebrandt, Kai Joachim Borm, Marciana Nona Duma

Abstract read
In one paragraph

Article in BMC medical imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Stefan KnippenDepartment of Radiotherapy and Radiation Oncology, University Hospital Jena, Friedrich Schiller University, Kastanienstraße 1, 07747, Jena, Germany. knippen@gmx.de.
Lea PargmannDepartment of Radiotherapy and Radiation Oncology, University Hospital Jena, Friedrich Schiller University, Kastanienstraße 1, 07747, Jena, Germany.
Steffen WeimannDepartment of Radiotherapy and Radiation Oncology, University Hospital Jena, Friedrich Schiller University, Kastanienstraße 1, 07747, Jena, Germany.
Guido HildebrandtDepartment of Radiation Oncology, University Medical Center Rostock, Rostock, Germany.
Kai Joachim BormDepartment of Radiation Oncology, TUM School of Medicine and Health, TUM University Hospital, Klinikum rechts der Isar, Munich, Germany.
Marciana Nona DumaDepartment of Radiotherapy and Radiation Oncology, University Hospital Jena, Friedrich Schiller University, Kastanienstraße 1, 07747, Jena, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDeformable Image Registration (DIR) is increasingly used in breast radiotherapy planning, but the impact of different parameter settings on clinical accuracy remains unclear. This study systematically evaluates how focus region selection and registration direction affect DIR performance, providing evidence-based recommendations for clinical implementation. MATERIALS AND

methodsWe analyzed 73 patients with left-sided breast cancer who underwent both free breathing (FB) and deep inspiration breath-hold (DIBH) planning CT scans. Clinical target volume (CTV), heart, left anterior descending artery, and both lungs were retrospectively contoured by one radiation oncologist on both datasets. Deformable Image Registration was performed bidirectionally (FB↔DIBH) using four different approaches: no focus region, CTV-focused, heart-focused, and surgical clip-focused registration. Volume differences and Dice Similarity Index (DSI) were calculated to assess registration accuracy. Generalized estimating equations analyzed possible correlations.

resultsFocus region selection critically impacted DIR accuracy. CTV-focused registration achieved highest CTV overlap (DSI: 0.96 vs. 0.91 without focus, p < 0.005) but compromised other structures. Heart-focused registration optimized cardiac structure accuracy but reduced CTV precision. Registration direction showed minimal impact on volume differences but affected DSI values. Tidal volume significantly affected both CTV (p < 0.005) and heart DSI (p < 0.007), with opposite effects on each structure. Manual contour adjustment remained necessary in all cases regardless of parameter selection.

conclusionDIR performance in breast radiotherapy is highly dependent on user-defined parameters, with no single configuration optimizing all structures simultaneously. Focus region selection creates a trade-off between local accuracy and global registration quality. Clinical implementation requires structure-specific parameter optimization and mandatory manual review. These findings establish practical limitations and benefits of hybrid DIR algorithms for breast radiotherapy workflows and highlight the continued necessity of expert oversight.

Indexed as

Breast NeoplasmsBreath HoldingRadiotherapy Planning, Computer-AssistedUnilateral Breast NeoplasmsAgedAlgorithmsFemaleHeartHumansInhalationMiddle AgedRetrospective StudiesTomography, X-Ray ComputedANACONDA algorithmBreast cancer radiotherapyClinical target volumeContour propagationDeep inspiration breath-holdDeformable image registrationDice similarity indexFocus region selection

Identifiers

PMID42249351
PMCPMC13295854

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.