Evidence map›Paper›PMID 42249160›Full record

ReviewClinical neuroradiology2026

Super-Bore Aspiration Catheters (≥ 0.088″) in Acute Ischemic Stroke: a Systematic Review and Meta-analysis.

Alperen Elek, Mohammed Seifuldin, Semra Yucel, Cem Bilgin, Ramanathan Kadirvel, David F Kallmes, Waleed Brinjikji

Abstract readReview
PubMed Publisher
In one paragraph

Review in Clinical neuroradiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alperen ElekEge University Faculty of Medicine, Izmir, Turkey. alperenelek13@gmail.com.
Mohammed SeifuldinAlfaisal University, Riyadh, Saudi Arabia.
Semra YucelDepartment of Internal Medicine, Izmir City Hospital, Izmir, Turkey.
Cem BilginDepartment of Radiology, Mayo Clinic, Rochester, United States.
Ramanathan KadirvelDepartment of Radiology, Mayo Clinic, Rochester, United States.
David F KallmesDepartment of Radiology, Mayo Clinic, Rochester, United States.
Waleed BrinjikjiDepartment of Radiology, Mayo Clinic, Rochester, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSuper-bore aspiration catheters with an inner diameter ≥ 0.088 inches have been developed to enhance clot ingestion, improve first-pass reperfusion, and reduce the need for adjunctive thrombectomy techniques in acute ischemic stroke. A comprehensive synthesis of their technical performance, angiographic efficacy, and safety profile is lacking.

methodsA systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. MEDLINE, Web of Science, and Scopus were searched from inception through December 7, 2025. Eligible studies included patients with acute ischemic stroke treated with super-bore aspiration catheters (inner diameter ≥ 0.088 inches). Pooled estimates were calculated using random-effects models.

resultsEleven studies comprising 835 patients were included. Successful delivery of the aspiration catheter to the target clot was achieved in 90.4% of cases (95% CI 84.82-94.13). Cross-over to stent retriever occurred in 11.95% (95% CI 4.89-26.37), and rescue therapy was required in 12.60% (95% CI 5.61-25.91). First pass effect (mTICI 2c-3) was achieved in 55.91% (95% CI 48.42-63.14), while modified first pass effect (mTICI ≥ 2b) occurred in 68.61% (95% CI 60.80-75.49). Final successful reperfusion (mTICI ≥ 2b) was achieved in 97.71% (95% CI 93.37-99.23), with near-complete or complete reperfusion (mTICI 2c-3) in 86.71% and complete reperfusion (mTICI 3) in 65.18% of cases. Symptomatic intracranial hemorrhage occurred in 1.93%, embolization to new territory in 1.62%, and total procedural complications in 3.80% of cases. Favorable functional outcome (mRS 0-2 at 90 days) was observed in 50.0%, while overall mortality was 16.87%.

conclusionSuper-bore aspiration catheters (≥ 0.088 inches) show high technical feasibility, comparable first pass reperfusion rates, and a favorable safety profile in the treatment of acute ischemic stroke.

Indexed as

Aspiration cathetersMechanical thrombectomyStrokeSuper-bore

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.