Evidence map›Paper›PMID 42248575›Full record

ArticleBMJ open quality2026

Wrong-side imaging orders: automated detection using electronic health record data - a retrospective cohort study.

Jerard Z Kneifati-Hayek, Isaac Peabody, Charles Baillie, Jiheum Park, Tian Gu, Jonathan Elias, Keith Hentel, Stella Kang, Chunhua Weng, Rachel C Shelton and 4 more

Abstract read
In one paragraph

Article in BMJ open quality, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Jerard Z Kneifati-HayekColumbia University Irving Medical Center, New York, New York, USA jk4197@cumc.columbia.edu.ORCID 0000-0002-8740-8409
Isaac PeabodyColumbia University Irving Medical Center, New York, New York, USA.
Charles BaillieMedicine, Columbia University Irving Medical Center, New York, New York, USA.
Jiheum ParkMedicine, Columbia University Irving Medical Center, New York, New York, USA.
Tian GuBiostatistics, Columbia University Mailman School of Public Health, New York, New York, USA.
Jonathan EliasPrimary Care, Weill Cornell Medicine, New York, New York, USA.
Keith HentelRadiology, NewYork-Presbyterian Hospital/Weill Cornell Medical Center, New York, New York, USA.
Stella KangColumbia University Department of Radiology, New York, New York, USA.
Chunhua WengColumbia University Department of Biomedical Informatics, New York, New York, USA.
Rachel C SheltonDepartment of Sociomedical Sciences, Columbia University Mailman School of Public Health, New York, New York, USA.
Joshua WeintraubColumbia University Department of Radiology, New York, New York, USA.
Michael RinkePediatrics, Children's Hospital at Montefiore and the Albert Einstein College of Medicine, Bronx, New York, USA.
Baruch S FertelQuality and Patient Safety, NewYork-Presbyterian Hospital, New York, New York, USA.
Jason S AdelmanMedicine, Columbia University Irving Medical Center, New York, New York, USA.ORCID 0000-0002-7497-257X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWrong-side diagnostic imaging order errors are preventable errors that can delay diagnosis and cause patient harm yet remain underdetected due to limitations in existing reporting systems.

objectiveTo develop and validate an automated electronic health record (EHR)-based method for detecting potential wrong-side diagnostic imaging order errors using an adapted Retract-and-Reorder (RAR) approach and to identify associated risk factors.

designRetrospective cohort study.

settingSix-facility health system comprising inpatient, outpatient and emergency room sites.

methodsWe screened 355 000 imaging orders with side specified, placed during 2021 across our healthcare system. We adapted the RAR methodology, originally developed to detect near-miss medication errors, by extending detection windows to 24 hours and identifying any orders switching from one side to the contralateral side, accounting for multiprovider workflows inherent in imaging. We validated the method through chart review of 100 randomly selected RAR events, then applied the query across all imaging orders. Multivariate logistic regression was used to identify risk factors associated with RAR events.

resultsWe identified 1667 RAR events (4.70 per 1000 orders). Validation yielded a positive predictive value of 87% (95% CI 79.0% to 92.2%), estimating 4.09 confirmed wrong-side errors per 1000 orders. The odds of an RAR event were significantly higher in outpatient settings compared with inpatient settings (OR 4.53; 95% CI 3.80 to 5.42) and among administrative staff compared with attending physicians (OR 2.08; 95% CI 1.73 to 2.49). CT scans showed 79% higher odds of an RAR event compared with X-rays (OR 1.79; 95% CI 1.34 to 2.39).

conclusionThis validated approach offers a scalable solution for automated detection of potential wrong-side diagnostic imaging order errors. The methodology leverages commonly available EHR data to support continuous surveillance and intervention evaluation for improved diagnostic safety.

Indexed as

Diagnostic ErrorsDiagnostic ImagingElectronic Health RecordsCohort StudiesFemaleHumansLogistic ModelsRetrospective StudiesAdverse events, epidemiology and detectionDiagnostic errorsPatient safety

Identifiers

PMID42248575
PMCPMC13250234

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.