Cross-Modal Characterization of Infant Cry: Validation of a Chest-Surface Accelerometer in Extracting Acoustic Vocal Function Measures.
Article in ArXiv, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Infant cry acoustics provide a promising window into early neurodevelopment and may serve as scalable biomarkers for neurodevelopmental disorders. However, conventional microphone-based recordings are highly susceptible to environmental noise and raise privacy concerns in real-world clinical settings. Chest-surface accelerometers may offer a robust alternative by capturing vibrations directly from the larynx. We evaluated the validity of a chest-mounted accelerometer (ACC) for infant cry analysis by comparing acoustic features derived from ACC and simultaneously recorded microphone (MIC) signals during routine vaccination visits. The final sample included 85 infants (41 at 4 months; 44 at 12 months) from a diverse pediatric population. Seven vocal measures were extracted from both modalities, including fundamental frequency (F0), jitter, shimmer, cepstral peak prominence (CPP), and harmonics-to-noise ratio (HNR). Agreement and consistency between modalities were assessed using intraclass correlation coefficients (ICCs). F0 demonstrated excellent agreement between ACC and MIC recordings (ICC > 0.94). Jitter measures also showed good-to-excellent agreement, while CPP demonstrated moderate agreement. Shimmer and HNR showed lower absolute agreement and systematic bias between modalities, reflecting possible differences in signal transmission and noise sensitivity. In summary, chest-surface accelerometers can reliably capture several clinically relevant acoustic features of infant cry, particularly temporal measures of F0 and jitter. This approach offers a noise-robust and privacy-preserving alternative to microphone-based recordings, supporting its potential use in scalable clinical and developmental research applications.